Southwire 58067299, VFD Cable 14 AWG 3C Copper RHH/RHW-2 TC-ER 2000V
Description
Southwire 58067299 is a 14 AWG, 3-conductor VFD cable with Class B compressed stranded bare copper conductors, cross-linked polyethylene (XLPE) Type RHH/RHW-2 insulation, a 5 mil copper tape shield and a polyvinyl chloride (PVC) jacket. It is Type TC-ER and rated 2000V. Three bare 18 AWG copper grounding conductors are included.
Southwire 58067299 Technical Specs
Construction
| Conductor Size | 14 AWG |
|---|---|
| Number of Conductors | 3, plus three grounding conductors |
| Conductor | Class B compressed stranded bare copper per ASTM B3 and ASTM B8 |
| Strands per Conductor | 7 |
| Insulation | Cross-linked polyethylene (XLPE), Type RHH/RHW-2 |
| Conductor Identification | Numbered conductors (1-One, 2-Two, 3-Three) |
| Grounding Conductors | Three 18 AWG Class B compressed stranded bare copper |
| Filler | Fillers as needed to make round |
| Shield | 5 mil copper tape shield with a minimum of 50% overlap |
| Jacket | Polyvinyl chloride (PVC) |
| Type Designation | TC-ER |
Dimensions and Weight
| Diameter Over Conductor | 0.07 in (0.18 cm) |
|---|---|
| Insulation Thickness | 60 mils (1.52 mm) |
| Diameter Over Shield | 0.451 in (1.15 cm) |
| Jacket Thickness | 60 mils (1.52 mm) |
| Approx. Overall Diameter | 0.571 in (1.45 cm) |
| Copper Weight | 93 lbs/1000 ft (138 kg/km) |
| Approx. Total Weight | 202 lbs/1000 ft (301 kg/km) |
Electrical and Thermal Ratings
| Voltage Rating | 2000V |
|---|---|
| Conductor Temperature | 90°C normal operation in wet and dry locations; 130°C emergency overload; 250°C short circuit |
Standards
| ASTM B3 | Soft or Annealed Copper Wire |
|---|---|
| ASTM B8 | Concentric-Lay-Stranded Copper Conductors |
| UL 44 | Thermoset-Insulated Wires and Cables |
| UL 1277 | Electrical Power and Control Tray Cables |
| UL 1685 | FT4 Vertical-Tray Fire Propagation and Smoke Release Test |
| ICEA S-95-658 (NEMA WC70) | Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy |
| ICEA S-138-738 | Power Cables Rated 2000 Volts or Less for use Between Variable Frequency Drives and Motors |
| IEEE 1202 FT4 | Flame Test (70,000) BTU/hr Vertical Tray Test |
| Made in America | Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661 |
Southwire 58067299 Applications
- Wet and dry areas: conduits, ducts, troughs and cable trays.
- Direct burial, and aerial runs supported by a messenger.
- Exposed runs as Type TC-ER per NEC 336.10.
- Class I, II and III, Division 2 per NEC Article 501 and 502.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.