Southwire 58074099, Metal Clad Cable 2 AWG 4C with Ground Stranded Copper THHN 600 V
Description
Southwire 58074099 is an Armorlite® Type MC cable with four 2 AWG 19-strand copper THHN/THWN conductors (brown, orange, yellow and gray), plus a 6 AWG green insulated THHN/THWN ground, under aluminum interlocked armor. It is rated 600 V with conductors rated 90°C dry.
Southwire 58074099 Technical Specs
Conductors and Insulation
| Conductor Size | 2 AWG |
|---|---|
| Number of Conductors | 4, plus a grounding conductor |
| Conductor | Class C compressed copper or combination unilay copper |
| Stranding | 19-strand |
| Conductor Colors | Brown, Orange, Yellow, Gray |
| Insulation | Polyvinyl chloride with nylon sheath, Type THHN/THWN |
| Insulation Thickness | 50 mils (1.27 mm) |
| Diameter Over Conductor | 0.286 in (0.73 cm) |
Grounding and Armor
| Grounding Conductor | Green insulated polyvinyl chloride with nylon sheath Type THHN/THWN ground, 6 AWG |
|---|---|
| Ground Size | 1x6 |
| Binder | Mylar tape with print legend, wrapped around the assembly |
| Armor | Aluminum interlocked armor |
Dimensions and Weight
| Diameter Over Armor | 1.238 in (3.14 cm) |
|---|---|
| Approximate Weight | 1197 lbs per 1,000 ft (1781 kg/km) |
Ratings
| Voltage Rating | 600 V |
|---|---|
| Conductor Temperature Rating | 90°C dry (Type THHN/THWN) |
| Location | Dry, indoor locations only (unjacketed Type MC, NEC 330.10(A)(10)) |
Standards
| ASTM B3 | Soft or Annealed Copper Wire |
|---|---|
| ASTM B8 | Concentric-Lay-Stranded Copper Conductors |
| ASTM B787 | 19 Wire Combination Unilay-Stranded Copper Conductors |
| UL 83 | Thermoplastic Insulated Wires and Cables |
| UL 1569 | Metal-Clad Cables |
| UL 1479 | Standard for Safety Fire Tests of Penetration Firestops |
| UL 1685 FT4 | Vertical-Tray Fire Propagation and Smoke Release Test |
| IEEE 1202 FT4 | Flame Test (70,000) BTU/hr Vertical Tray Test |
| RoHS-2 | European Directive 2011/65/EU |
| Buy American | Compliant with Buy American Requirements, found in 49 U.S.C. § 5323(j), when ordered as “Made in the USA Only!” |
| Federal Specification | Meets or exceeds A-A59544 (formerly J-C-30B) |
| NFPA 70 (NEC) | Meets or exceeds Article 330 |
Southwire 58074099 Applications
- Branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings.
- Fished or embedded in plaster.
- Concealed or exposed runs.
- Environmental air-handling spaces per NEC 300.22(C).
- Places of assembly per NEC 518.4 and theaters per NEC 520.5.
- Cable tray and approved raceways.
- Under raised floors for information technology equipment conductors and cables per NEC Article 645.
- Class I Div. 2, Class II Div. 2 and Class III Div. 1.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.