Southwire 58223809, Power Tray Cable 8 AWG 3C Aluminum Alloy XHHW-2 TC-ER 1000V Black
Description
Southwire 58223809 is an 8 AWG 3-conductor power tray cable with 7-strand Class B compact stranded 8000 Series aluminum alloy conductors, cross-linked polyethylene (XLPE) Type XHHW-2 insulation and a black PVC jacket. It is Type TC-ER and rated 1000V. A bare 8 AWG aluminum alloy grounding conductor is included in addition to the 3 circuit conductors. The conductors are colour coded brown, orange and yellow.
Southwire 58223809 Technical Specs
Construction
| Conductor Size | 8 AWG |
|---|---|
| Number of Conductors | 3 |
| Conductor | Class B compact stranded 8000 Series aluminum alloy per ASTM B800 and ASTM B836 |
| Strands per Conductor | 7 |
| Insulation | Cross-linked polyethylene (XLPE), Type XHHW-2 |
| Conductor Colours | Brown, Orange, Yellow |
| Grounding Conductor | One 8 AWG bare grounding conductor, Class B compact stranded 8000 Series aluminum alloy |
| Filler | Polypropylene filler |
| Jacket | Sunlight-resistant polyvinyl chloride (PVC) |
| Jacket Colour | Black |
| Type Designation | TC-ER |
Dimensions and Weight
| Diameter Over Conductor | 0.134 in (0.34 cm) |
|---|---|
| Insulation Thickness | 45 mils (1.14 mm) |
| Jacket Thickness | 60 mils (1.52 mm) |
| Approx. Overall Diameter | 0.666 in (1.69 cm) |
| Aluminum Weight | 62 lbs/1000 ft (92 kg/km) |
| Approx. Total Weight | 189 lbs/1000 ft (281 kg/km) |
Electrical and Thermal Ratings
| Voltage Rating | 1000V |
|---|---|
| Conductor Temperature | 90°C wet and dry; 130°C emergency overload; 250°C short circuit |
| Environmental | Sunlight resistant; silicone free |
Standards
| ASTM B800 | 8000 Series Aluminum Alloy Wire |
|---|---|
| ASTM B836 | Compact Rounded Stranded Aluminum Conductors |
| UL 44 | Thermoset-Insulated Wires and Cables |
| UL 1277 | Electrical Power and Control Tray Cables |
| UL 1685 | Vertical-Tray Fire Propagation and Smoke Release Test |
| ICEA S-95-658 (NEMA WC70) | Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy |
| IEEE 1202 FT4 | Flame Test (70,000) BTU/hr Vertical Tray Test |
Southwire 58223809 Applications
- Wet and dry areas, in conduits, ducts, troughs and cable trays.
- Direct burial, and aerial runs supported by a messenger.
- Class I, II and III, Division 2 per NEC Article 501 and 502.
- Exposed runs (TC-ER) per NEC 336.10.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.