Southwire 58395799 is a 250 KCMIL three-conductor Type TECK 90 armored power cable rated 1 kV CSA / 600 V UL. Its three 35-strand 8000 Series aluminum conductors carry 90 mils of XLPE, and one 2 AWG uninsulated aluminum grounding conductor runs with them. A black PVC inner jacket, aluminum interlocked armor (AIA) and a black PVC outer jacket complete the cable.
Southwire 58395799 Technical Specs
Conductors & Insulation
| Conductor Size | 250 KCMIL |
|---|---|
| Number of Conductors | 3 |
| Strands per Conductor | 35 |
| Conductor | Class B compact stranded 8000 Series aluminum |
| Insulation | Cross-linked polyethylene (XLPE) |
| Insulation Thickness | 90 mils (2.29 mm) |
| Conductor Colors | Black, numbered |
| Diameter Over Conductor | 0.520 in (1.32 cm) |
Grounding, Armor & Jacket
| Grounding Conductor | One 2 AWG uninsulated aluminum Class B stranded grounding conductor |
|---|---|
| Binder | Polypropylene tape |
| Inner Jacket | Black polyvinyl chloride (PVC) |
| Inner Jacket Thickness | 115 mils (2.92 mm) |
| Armor | Aluminum interlocked armor (AIA) |
| Diameter Over Armor | 2.099 in (5.33 cm) |
| Outer Jacket | Black polyvinyl chloride (PVC) |
| Jacket Thickness | 65 mils (1.65 mm) |
Dimensions & Weight
| Approximate Outside Diameter | 2.231 in (5.67 cm) |
|---|---|
| Approximate Weight | 2104 lbs/1000 ft (3131 kg/km) |
| Maximum Pull Tension | 4500 lbs (2041.16 kg) |
| Minimum Bend Radius | 15.6 in (39.62 cm) |
Ratings & Compliance
| Voltage Rating | 1 kV CSA / 600 V UL |
|---|---|
| Type Designation | Type TECK 90 |
| Standards | ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy; ASTM B836 Compact Rounded Stranded Aluminum Conductors; UL 1569 Metal-Clad Cables; CSA C22.2 No. 174; CSA C22.2 No. 131 Type TECK 90 Cable; CSA C22.2 No. 2556 & No. 0.3 Wire and Cable Test Methods; CSA HL rating; CSA SUN RES - for Sunlight Resistant rating; IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test |
Southwire 58395799 Applications
- Exposed or concealed wiring in wet or dry locations.
- Ventilated, non-ventilated and ladder-type cable troughs and ventilated flexible cableway, in wet, dry or classified locations, or direct buried.
- Control, lighting and power circuits in pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants.
- Sunlight resistant.