Southwire 58560102, Metal Clad Cable 12 AWG 2C with Ground Stranded Copper THHN Black Jacket
Description
Southwire 58560102 is an Armorlite® jacketed Type MC cable with two 12 AWG 19-strand copper THHN/THWN conductors (yellow and white) and a green insulated ground under aluminum interlocked armor and a black PVC jacket. The PVC jacket is sunlight and corrosion resistant, the conductors are rated 90°C dry and 75°C wet, and the cable is suitable for wet locations per NEC 330.10(A)(11).
Southwire 58560102 Technical Specs
Conductors and Insulation
| Conductor Size | 12 AWG |
|---|---|
| Number of Conductors | 2, plus a grounding conductor |
| Conductor | 19-strand class C compressed copper per ASTM B3 and ASTM B8 |
| Stranding | 19-strand |
| Conductor Colors | Yellow, White |
| Insulation | Polyvinyl chloride with nylon sheath, Type THHN/THWN |
| Insulation Thickness | 20 mils (0.51 mm) |
| Diameter Over Conductor | 0.088 in (0.22 cm) |
Grounding, Armor and Jacket
| Grounding | Green insulated ground, polyvinyl chloride with nylon sheath Type THHN/THWN |
|---|---|
| Ground Size | 1x12 |
| Binder | Mylar tape |
| Armor | Aluminum interlocked armor |
| Jacket | Black PVC, sunlight resistant and corrosion resistant |
| Jacket Thickness | 50 mils (1.27 mm) |
Dimensions and Weight
| Diameter Over Armor | 0.505 in (1.28 cm) |
|---|---|
| Approximate Outside Diameter | 0.611 in (1.55 cm) |
| Approximate Weight | 181 lbs per 1,000 ft (269 kg/km) |
Ratings
| Conductor Temperature | 90°C dry, 75°C wet (Type THHN/THWN) |
|---|---|
| Location | Suitable for wet locations per NEC 330.10(A)(11) |
| Anti-Short Bushing | Not required |
Standards
| ASTM B3 | Soft or Annealed Copper Wire |
|---|---|
| ASTM B8 | Concentric-Lay-Stranded Copper Conductors |
| UL 83 | Thermoplastic Insulated Wires and Cables |
| UL 1569 | Metal-Clad Cables |
| UL 1479 | Fire Tests of Penetration Firestops |
| UL 1685 FT4 | Vertical-Tray Fire Propagation and Smoke Release Test |
| IEEE 1202 FT4 | Flame Test (70,000) BTU/hr Vertical Tray Test |
| RoHS-2 | European Directive 2011/65/EU |
| Buy American | Compliant with Buy American Requirements, found in 49 U.S.C. § 5323(j), when ordered as “Made in the USA Only!” |
| Meets or Exceeds | Federal Specification A-A59544 (formerly J-C-30B); NFPA 70 (National Electrical Code), Article 330 |
Southwire 58560102 Applications
- Branch and service power distribution in commercial, industrial, institutional and multi-residential buildings.
- Exposure to cinder fills, strong chlorides, caustic alkalis, or vapors of chlorine or of hydrochloric acids.
- Fished or embedded in plaster.
- Concealed or exposed runs.
- Places of assembly per NEC 518.4 and theaters per NEC 520.5.
- Cable tray and approved raceways, or aerial runs on a messenger.
- Under raised floors for information technology equipment conductors and cables per NEC Article 645.
- Class I Div. 2, Class II Div. 2 and Class III Div. 1.