Southwire 58667499 is a 3/0 AWG three-conductor Type MC-HL ARMOR-X® power cable rated 600 V. Its three 19-strand compressed copper conductors carry 55 mils of XHHW-2 XLPE, and three 8 AWG bare copper grounding conductors run with them. ARMOR-X® continuous corrugated welded armor and a black Solonon LSZH-TP outer jacket complete the cable.
Southwire 58667499 Technical Specs
Conductors & Insulation
| Conductor Size | 3/0 AWG |
|---|---|
| Number of Conductors | 3 |
| Strands per Conductor | 19 |
| Conductor | Class B compressed stranded bare copper per ASTM B3 and B8 |
| Insulation | Cross-linked polyethylene (XLPE), Type XHHW-2 |
| Insulation Thickness | 55 mils (1.40 mm) |
| Conductor Colors | 1-Black, 2-Red, 3-Blue |
| Diameter Over Conductor | 0.456 in (1.16 cm) |
Grounding, Armor & Jacket
| Grounding Conductors | Three 8 AWG Class B compressed stranded bare copper |
|---|---|
| Filler | Paper (polypropylene on 8 and 6 AWG sizes) |
| Binder | Polypropylene tape |
| Armor | ARMOR-X® continuous corrugated welded armor |
| Diameter Over Armor | 1.540 in (3.91 cm) |
| Outer Jacket | Black thermoplastic Solonon® low smoke zero halogen (LSZH-TP) |
| Jacket Thickness | 60 mils (1.52 mm) |
Dimensions & Weight
| Approximate Outside Diameter | 1.660 in (4.22 cm) |
|---|---|
| Approximate Weight | 2427 lbs/1000 ft (3612 kg/km) |
| Maximum Pull Tension | 4027 lbs (1826.61 kg) |
| Minimum Bend Radius | 11.6 in (29.46 cm) |
Ratings & Compliance
| Voltage Rating | 600 V |
|---|---|
| Type Designation | Type MC-HL |
| Operating Temperatures | 90°C normal operation (wet and dry locations); 130°C emergency overload; 250°C short circuit |
| Cold Bend | -50°C |
| Location Rating | Class I, II, and III, Division 1 and 2 per NEC Article 501, 502, and 503 |
| VFD Use | Suitable for VFD application (three ground wires) |
| Standards | ASTM B3 Soft or Annealed Copper Wire; ASTM B8 Concentric-Lay-Stranded Copper Conductors; UL 44 Thermoset-Insulated Wires and Cables; UL 1569 Metal-Clad Cables; UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger); UL 2225 Cables and Cable-Fittings For Use In Classified Locations; ICEA S-58-679 Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE); ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy; ICEA S-138-738 Power Cables Rated 2000 Volts or Less for use Between Variable Frequency Drives and Motors; IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test |
Southwire 58667499 Applications
- Wet and dry areas, conduits, ducts, troughs and trays, along with direct burial and aerial runs supported by a messenger.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.