Southwire 58754202, Metal Clad Cable 10 AWG 2C with Ground Stranded Copper THHN 600 V
Description
Southwire 58754202 is an Armorlite® Type MC neutral-per-phase cable with two 10 AWG 19-strand copper Type THHN/THWN conductors in yellow and gray-yellow, one of them a neutral, plus a green insulated Type THHN/THWN ground conductor, under aluminum interlocked armor. Rated 600 V; conductors rated 90°C dry as Type THHN/THWN. Unjacketed, for dry, indoor locations only.
Southwire 58754202 Technical Specs
Conductors and Insulation
| Conductor Size | 10 AWG |
|---|---|
| Number of Conductors | 2 (one of them the neutral), plus one grounding conductor |
| Neutral Conductors | 1 x 10 AWG |
| Conductor | 19-strand class C compressed copper per ASTM B3 and B8 |
| Stranding | 19-strand |
| Conductor Colors | Yellow, Gray-Yellow; green (ground) |
| Insulation | Polyvinyl chloride with nylon sheath, Type THHN/THWN |
| Insulation Thickness | 25 mils (0.64 mm) |
| Diameter Over Conductor | 0.113 in (0.29 cm) |
Grounding and Armor
| Grounding | Green insulated polyvinyl chloride with nylon sheath Type THHN/THWN ground conductor |
|---|---|
| Ground Size | 1x10 |
| Binder | Mylar tape; binder tape with print legend wrapped around the assembly |
| Armor | Aluminum interlocked armor |
Dimensions and Weight
| Diameter Over Armor | 0.574 in (1.46 cm) |
|---|---|
| Approximate Weight | 162 lbs per 1,000 ft (241 kg/km) |
Ratings
| Voltage Rating | 600 V |
|---|---|
| Conductor Temperature Rating | 90°C dry, Type THHN/THWN |
| Location | Dry, indoor locations only (unjacketed Type MC, NEC 330.10(A)(10)) |
Standards
| ASTM B3 | Soft or Annealed Copper Wire |
|---|---|
| ASTM B8 | Concentric-Lay-Stranded Copper Conductors |
| UL 83 | Thermoplastic Insulated Wires and Cables |
| UL 1569 | Metal-Clad Cables |
| UL 1479 | Standard for Safety Fire Tests of Penetration Firestops |
| UL 1685 FT4 | Vertical-Tray Fire Propagation and Smoke Release Test |
| IEEE 1202 FT4 | Flame Test (70,000) BTU/hr Vertical Tray Test |
| Buy American | Compliant with Buy American Requirements, found in 49 U.S.C. § 5323(j), when ordered as “Made in the USA Only!” |
| Federal Specification | Meets or exceeds A-A59544 (formerly J-C-30B) |
| NFPA 70 (NEC) | Meets or exceeds Article 330 |
Southwire 58754202 Applications
Neutral-per-phase construction complying with NEC 200.4 for the installation and marking of neutral conductors; no neutral is to be used for more than one circuit (branch, multiwire branch or ungrounded feeder).
- Circuits affected by harmonics from non-linear switching loads such as computers, variable frequency drives, electrical test equipment and office equipment.
- Multiple circuits for branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings.
- Fished or embedded in plaster.
- Concealed or exposed installations.
- Environmental air-handling spaces per NEC 300.22(C).
- Places of assembly per NEC 518.4 and theaters per NEC 520.5.
- Cable tray and approved raceways.
- Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) and 645.5(D)(2).
- Class I Div. 2, Class II Div. 2 and Class III Div. 1.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.