Southwire 58919601, Building Wire 500 KCMIL Aluminum XHHW-2/RW90 Purple
Description
Southwire 58919601 is a 500 KCMIL aluminum SIMpull XHHW-2/RW90 building wire in purple, from Southwire's XHHW-2/RW90 line with AlumaFlex Brand conductors. Its 34-strand compact aluminum conductor carries flame-retardant, moisture-resistant thermoset cross-linked polyethylene (XLPE) insulation with patented SIMpull Technology, so it can be pulled without lubricant. Rated up to 1000 volts for all applications, in wet or dry locations at temperatures not exceeding 90°C.
Southwire 58919601 Technical Specs
Construction
| Conductor Size | 500 KCMIL |
|---|---|
| Metric Cross-Section | 253 mm² |
| Conductor | Class B compact stranded bare aluminum per ASTM B800 and ASTM B801, or Single Input Wire (SIW) compact aluminum per ASTM B836 |
| Number of Strands | 34 |
| Insulation | Flame-retardant, moisture-resistant thermoset cross-linked polyethylene (XLPE) with SIMpull Technology |
| Type Designation | XHHW-2/RW90 |
| Insulation Colour | Purple |
Dimensions and Weight
| Diameter Over Conductor | 0.735 in (1.87 cm) |
|---|---|
| Insulation Thickness | 65 mils (1.65 mm) |
| Approx. Overall Diameter | 0.876 in (2.23 cm) |
| Aluminum Content Weight | 471 lbs/1000 ft (701 kg/km) |
| Approx. Total Weight | 557 lbs/1000 ft (829 kg/km) |
Ratings
| Voltage | Up to 1000 volts, all applications |
|---|---|
| Temperature | Wet or dry locations, not to exceed 90°C |
Features
| Oil and Gasoline | Gas and Oil Resistant II, all sizes |
|---|---|
| Sunlight | Sunlight Resistant, sizes 6 AWG and larger |
| Cable Tray | CT Rated, sizes 1/0 AWG and larger |
| Flame Test | FT4, 350 kcmil and larger |
| Federal Specification | AA-59544 |
| RoHS/REACH | Compliant |
Standards
| ASTM B800 | 8000 Series Aluminum Alloy Wire |
|---|---|
| ASTM B801 | Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy |
| ASTM B836 | Compact Rounded Stranded Aluminum Conductors |
| UL 44 | Thermoset-Insulated Wires and Cables |
| CSA C22.2 No. 38 | Thermoset-insulated wires and cables |
| ICEA S-95-658 (NEMA WC70) | Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy |
| NMX-J-451-ANCE | Thermoset insulated wires and cables |
| NOM-063-SCFI | Electrical Products – Conductors – Safety Requirements |
Southwire 58919601 Applications
- Pulled into conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications, as specified in the National Electrical Code.
- It is suitable for use in health care facilities per section 517.160 of the NEC where a dielectric constant of 3.5 or less may be specified.
- Under its RW90 designation it serves open wiring, including open wiring exposed to the weather, and raceways (except cable troughs and ventilated flexible cableways) in dry or wet locations, as per the Canadian Electrical Code.
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.