Description
Southwire 58950001 is a 4/0 AWG single-conductor ROYAL GUARD™ power cable with Class B compressed stranded tinned copper, lead free ethylene propylene rubber (EPR) Type RHH/RHW-2 insulation and a black lead free, silicone-free thermoset chlorinated polyethylene (CPE-TS) jacket. It is rated 600V.
Southwire 58950001 Technical Specs
Construction
| Conductor Size | 4/0 AWG |
|---|---|
| Number of Conductors | 1 |
| Strands | 19 |
| Conductor | Class B compressed stranded tinned copper per ASTM B33 and ASTM B8 |
| Binder Tape | Mylar tape |
| Insulation | Lead free ethylene propylene rubber (EPR), Type RHH/RHW-2 |
| Jacket | Lead free and silicone-free cross-linked/thermoset chlorinated polyethylene (CPE-TS) |
| Jacket Colour | Black |
Dimensions and Weight
| Diameter Over Conductor | 0.512 in (1.30 cm) |
|---|---|
| Insulation Thickness | 55 mils (1.40 mm) |
| Jacket Thickness | 45 mils (1.14 mm) |
| Approx. Overall Diameter | 0.728 in (1.85 cm) |
| Copper Weight | 653 lbs/1000 ft (972 kg/km) |
| Approx. Total Weight | 780 lbs/1000 ft (1161 kg/km) |
Electrical and Thermal Ratings
| Voltage Rating | 600V |
|---|---|
| Conductor Temperature | 90°C normal operation in wet and dry locations; 130°C emergency overload; 250°C short circuit |
| Environmental | CT rated 1/0 and larger; Sunlight resistant; oil resistant; silicone free |
Standards
| ASTM B3 | Soft or Annealed Copper Wire |
|---|---|
| ASTM B8 | Concentric-Lay-Stranded Copper Conductors |
| ASTM B33 | Standard Specification for Tin-Coated Soft or Annealed Copper Wire |
| UL 44 | Thermoset-Insulated Wires and Cables |
| UL 1685 FT4 | Vertical-Tray Fire Propagation and Smoke Release Test |
| ICEA S-95-658 (NEMA WC70) | Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy |
| IEEE 1202 FT4 | Flame Test (70,000) BTU/hr Vertical Tray Test |
| VW-1 | Vertical-Wire Flame Test |
| CT USE | Sizes 1/0 AWG and Larger |
Southwire 58950001 Applications
- Wet and dry areas.
- Conduits, ducts, troughs and cable trays.
- Direct burial.
- Aerial installation supported by a messenger.
- Class I, II and III, Division 2 per NEC Articles 501 and 502.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.