Southwire 59111699, Building Wire 4 AWG Aluminum XHHW-2/RW90 White
Description
Southwire 59111699 is a 4 AWG aluminum SIMpull XHHW-2/RW90 building wire in white, from Southwire's XHHW-2/RW90 line with AlumaFlex Brand conductors. Its 7-strand compact aluminum conductor carries flame-retardant, moisture-resistant thermoset cross-linked polyethylene (XLPE) insulation with patented SIMpull Technology, so it can be pulled without lubricant. Rated up to 1000 volts for all applications, in wet or dry locations at temperatures not exceeding 90°C.
Southwire 59111699 Technical Specs
Construction
| Conductor Size | 4 AWG |
|---|---|
| Metric Cross-Section | 21.2 mm² |
| Conductor | Class B compact stranded bare aluminum per ASTM B800 and ASTM B801, or Single Input Wire (SIW) compact aluminum per ASTM B836 |
| Number of Strands | 7 |
| Insulation | Flame-retardant, moisture-resistant thermoset cross-linked polyethylene (XLPE) with SIMpull Technology |
| Type Designation | XHHW-2/RW90 |
| Insulation Colour | White |
Dimensions and Weight
| Diameter Over Conductor | 0.212 in (0.54 cm) |
|---|---|
| Insulation Thickness | 45 mils (1.14 mm) |
| Approx. Overall Diameter | 0.309 in (0.78 cm) |
| Aluminum Content Weight | 39 lbs/1000 ft (58 kg/km) |
| Approx. Total Weight | 58 lbs/1000 ft (86 kg/km) |
Ratings
| Voltage | Up to 1000 volts, all applications |
|---|---|
| Temperature | Wet or dry locations, not to exceed 90°C |
Features
| Oil and Gasoline | Gas and Oil Resistant II, all sizes |
|---|---|
| Sunlight | Sunlight Resistant, sizes 6 AWG and larger |
| Federal Specification | AA-59544 |
| RoHS/REACH | Compliant |
Standards
| ASTM B800 | 8000 Series Aluminum Alloy Wire |
|---|---|
| ASTM B801 | Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy |
| ASTM B836 | Compact Rounded Stranded Aluminum Conductors |
| UL 44 | Thermoset-Insulated Wires and Cables |
| CSA C22.2 No. 38 | Thermoset-insulated wires and cables |
| ICEA S-95-658 (NEMA WC70) | Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy |
| NMX-J-451-ANCE | Thermoset insulated wires and cables |
| NOM-063-SCFI | Electrical Products – Conductors – Safety Requirements |
Southwire 59111699 Applications
- Pulled into conduit for services, feeders and branch circuits in commercial or industrial applications, as specified in the National Electrical Code.
- It is suitable for use in health care facilities per section 517.160 of the NEC where a dielectric constant of 3.5 or less may be specified.
- Under its RW90 designation it serves open wiring, including open wiring exposed to the weather, and raceways (except cable troughs and ventilated flexible cableways) in dry or wet locations, as per the Canadian Electrical Code.
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.