Southwire 59195099, Control Tray Cable 14 AWG 7C Tinned Copper XHHW-2 TC-ER 1000V Black
Description
Southwire 59195099 is a 14 AWG, 7-conductor control tray cable with tinned copper conductors, ethylene propylene rubber (EPR) Type XHHW-2 insulation and a black thermoplastic chlorinated polyethylene (CPE-TP) jacket. It is Type TC-ER and rated 1000V.
Southwire 59195099 Technical Specs
Construction
| Conductor Size | 14 AWG |
|---|---|
| Number of Conductors | 7 |
| Conductor | Class B compressed tinned copper per ASTM B33 and B8 |
| Strands per Conductor | 7 |
| Insulation | Ethylene propylene rubber (EPR), Type XHHW-2 |
| Conductor Identification | Black, Red, Blue, Orange, Yellow, Brown, Red-black Stripe |
| Binder | Polyester flat thread binder tape |
| Jacket | Thermoplastic chlorinated polyethylene (CPE-TP) |
| Jacket Colour | Black |
| Type Designation | TC-ER |
Dimensions and Weight
| Insulation Thickness | 30 mils (0.76 mm) |
|---|---|
| Jacket Thickness | 45 mils (1.14 mm) |
| Approx. Overall Diameter | 0.502 in (1.28 cm) |
| Minimum Bend Radius | 2.0 in (5.08 cm) |
| Copper Weight | 87 lbs/1000 ft (129 kg/km) |
| Approx. Weight | 170 lbs/1000 ft (253 kg/km) |
Electrical and Thermal Ratings
| Voltage Rating | 1000V |
|---|---|
| Conductor Temperature | 90°C normal operation in wet and dry locations; 130°C emergency overload; 250°C short circuit |
| DC Resistance at 25°C | 2.631 |
| AC Resistance at 75°C | 3.170 |
| Allowable Ampacity, Raceway, 75°C | 14 |
| Allowable Ampacity, Raceway, 90°C | 17 |
| Other Ratings | Sunlight resistant; silicone free |
Standards
| ASTM B8 | Concentric-Lay-Stranded Copper Conductors |
|---|---|
| ASTM B33 | Standard Specification for Tin-Coated Soft or Annealed Copper Wire |
| UL 44 | Thermoset-Insulated Wires and Cables |
| UL 44 VW-1 | Vertical flame test on individual conductors |
| UL 1277 | Electrical Power and Control Tray Cables |
| UL 1685 FT4 | Vertical-Tray Fire Propagation and Smoke Release Test |
| ICEA S-58-679 | Control Cable Conductor Identification Method 1 Table 2 |
| ICEA S-73-532 | Standard for Control, Thermocouple Extension and Instrumentation Cables |
| ICEA S-95-658 (NEMA WC70) | Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy |
| IEEE 1202 FT4 | Flame Test (70,000) BTU/hr Vertical Tray Test |
Southwire 59195099 Applications
- Wet and dry areas, in conduits, ducts, troughs and cable trays.
- Direct burial, and aerial runs supported by a messenger.
- Exposed runs (TC-ER) per NEC 336.10.
- Class I, II and III, Division 2 per NEC Article 501 and 502.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.