Southwire 59198299, Power Tray Cable 8 AWG 4C Tinned Copper XHHW-2 TC 600V Black
Description
Southwire 59198299 is an 8 AWG, 4-conductor power tray cable with tinned copper conductors, ethylene propylene rubber (EPR) Type XHHW-2 insulation and a black thermoplastic chlorinated polyethylene (CPE-TP) jacket. It is Type TC and rated 600V. A 10 AWG tinned copper grounding conductor is included in addition to the 4 circuit conductors.
Southwire 59198299 Technical Specs
Construction
| Conductor Size | 8 AWG |
|---|---|
| Number of Conductors | 4 |
| Conductor | Class B compressed stranded tinned copper per ASTM B33 and B8 |
| Strands per Conductor | 7 |
| Insulation | Ethylene propylene rubber (EPR), Type XHHW-2 |
| Conductor Identification | Numbered conductors: 1-ONE, 2-TWO, 3-THREE, 4-FOUR |
| Grounding Conductor | One 10 AWG Class B compressed stranded tinned copper, in addition to the 4 circuit conductors |
| Filler | Polypropylene |
| Jacket | Thermoplastic chlorinated polyethylene (CPE-TP) |
| Jacket Colour | Black |
| Type Designation | TC |
Dimensions and Weight
| Diameter Over Conductor | 0.141 in (0.36 cm) |
|---|---|
| Insulation Thickness | 45 mils (1.14 mm) |
| Jacket Thickness | 60 mils (1.52 mm) |
| Approx. Overall Diameter | 0.724 in (1.84 cm) |
| Copper Weight | 238 lbs/1000 ft (354 kg/km) |
| Approx. Weight | 385 lbs/1000 ft (573 kg/km) |
Electrical and Thermal Ratings
| Voltage Rating | 600V |
|---|---|
| Conductor Temperature | 90°C normal operation in wet and dry locations; 130°C emergency overload; 250°C short circuit |
Standards
| ASTM B8 | Concentric-Lay-Stranded Copper Conductors |
|---|---|
| ASTM B33 | Standard Specification for Tin-Coated Soft or Annealed Copper Wire |
| UL 44 | Thermoset-Insulated Wires and Cables |
| UL 44 VW-1 | Vertical flame test on individual conductors |
| UL 1277 | Electrical Power and Control Tray Cables |
| UL 1685 FT4 | Vertical-Tray Fire Propagation and Smoke Release Test |
| ICEA S-95-658 (NEMA WC70) | Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy |
| IEEE 1202 FT4 | Flame Test (70,000) BTU/hr Vertical Tray Test |
Southwire 59198299 Applications
- Wet and dry areas, in conduits, ducts, troughs and cable trays.
- Direct burial, and aerial runs supported by a messenger.
- Class I, II and III, Division 2 per NEC Article 501 and 502.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.