Southwire 59224501, Metal Clad Cable 12 AWG 2C with Ground Solid Copper THHN plus 16 AWG Signal Pair
Description
Southwire 59224501 is an MC-PCS Duo™ Type MC power and control/signal cable with a power element and a signal element under one aluminum interlocked armor. The power element is two 12 AWG solid copper THHN/THWN conductors, brown and gray, with a green insulated ground; the signal element is a pair of 16 AWG solid copper Type TFN singles, pink and purple, under a light blue PVC jacket. Conductors rated 90°C dry as Type THHN/THWN. Unjacketed, for dry, indoor locations only.
Southwire 59224501 Technical Specs
Conductors and Insulation
| Conductor Size | 12 AWG |
|---|---|
| Number of Conductors | 2 power conductors, plus one grounding conductor and a 16 AWG signal pair |
| Conductor | Solid copper per ASTM B3 |
| Stranding | Solid |
| Conductor Colors | Brown, Gray; green (ground) |
| Insulation | Polyvinyl chloride with nylon sheath, Type THHN/THWN |
| Insulation Thickness | 20 mils (0.51 mm) |
| Diameter Over Conductor | 0.080 in (0.20 cm) |
| Signal Pair | Two 16 AWG solid copper Type TFN insulated singles, pink and purple, under an overall light blue PVC jacket |
Grounding and Armor
| Grounding | Green insulated polyvinyl chloride with nylon sheath Type THHN/THWN ground conductor |
|---|---|
| Ground Size | 1x12 |
| Binder | Mylar tape; binder tape with print legend wrapped around the assembly |
| Armor | Aluminum interlocked armor |
Dimensions and Weight
| Diameter Over Armor | 0.608 in (1.54 cm) |
|---|---|
| Approximate Weight | 153 lbs per 1,000 ft (228 kg/km) |
Ratings
| Conductor Temperature Rating | 90°C dry, Type THHN/THWN |
|---|---|
| Location | Dry, indoor locations only (unjacketed Type MC, NEC 330.10(A)(10)) |
| Anti-Short Bushing | Not required |
Standards
| ASTM B3 | Soft or Annealed Copper Wire |
|---|---|
| ASTM B8 | Concentric-Lay-Stranded Copper Conductors |
| UL 66 | Fixture Wire Type TFN |
| UL 83 | Thermoplastic Insulated Wires and Cables |
| UL 1569 | Metal-Clad Cables |
| UL 1479 | Standard for Safety Fire Tests of Penetration Firestops |
| UL 1685 FT4 | Vertical-Tray Fire Propagation and Smoke Release Test |
| IEEE 1202 FT4 | Flame Test (70,000) BTU/hr Vertical Tray Test |
| Buy American | Compliant with Buy American Requirements, found in 49 U.S.C. § 5323(j), when ordered as “Made in the USA Only!” |
| Federal Specification | Meets or exceeds A-A59544 (formerly J-C-30B) |
| NFPA 70 (NEC) | Meets or exceeds Article 330 |
Southwire 59224501 Applications
- Branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings.
- Fished or embedded in plaster.
- Concealed or exposed installations.
- LED lighting with 0-10V dimming.
- Environmental air-handling spaces per NEC 300.22(C).
- Places of assembly per NEC 518.4 and theaters per NEC 520.5.
- Cable tray and approved raceways.
- Under raised floors for information technology equipment conductors and cables per NEC 645.
- Class I Div. 2, Class II Div. 2 and Class III Div. 1.