Southwire 59337599, Power Tray Cable 500 kcmil 4C Copper THHN TC-ER 600V Black
Description
Southwire 59337599 is a 500 kcmil, 4-conductor Type TC-ER power tray cable with Class B compressed stranded bare copper conductors, polyvinyl chloride (PVC) with nylon layer Type THHN/THWN-2 insulation, one 250 kcmil bare copper grounding conductor, paper filler, polyester binder tape and a black polyvinyl chloride (PVC) jacket, rated 600V.
Southwire 59337599 Technical Specs
Construction
| Conductor Size | 500 kcmil |
|---|---|
| Number of Conductors | 4 |
| Strands per Conductor | 37 |
| Conductor | Class B compressed stranded bare copper per ASTM B3 and B8 |
| Insulation | Polyvinyl chloride (PVC) with nylon layer, Type THHN/THWN-2 |
| Conductor Identification | 1-BLACK, 2-RED, 3-BLUE, 4-ORANGE |
| Grounding Conductor | One 250 kcmil Class B compressed stranded bare copper |
| Filler | Paper |
| Binder | Polyester flat thread binder tape |
| Jacket | Polyvinyl chloride (PVC) |
| Jacket Colour | Black |
| Type Designation | TC-ER |
Dimensions and Weight
| Diameter Over Conductor | 0.789 in (2.00 cm) |
|---|---|
| Insulation Thickness | 60 mils (1.52 mm) |
| Jacket Thickness | 110 mils (2.79 mm) |
| Approx. Overall Diameter | 2.485 in (6.31 cm) |
| Copper Weight | 7016 lbs/1000 ft (10441 kg/km) |
| Approx. Total Weight | 8077 lbs/1000 ft (12020 kg/km) |
Electrical and Thermal Ratings
| Voltage Rating | 600V |
|---|---|
| Conductor Temperature | 90°C in wet and dry locations; 105°C emergency overload; 250°C short circuit |
| Environmental | Sunlight resistant; silicone free |
Standards
| ASTM B3 | Soft or Annealed Copper Wire |
|---|---|
| ASTM B8 | Concentric-Lay-Stranded Copper Conductors |
| UL 83 | Thermoplastic Insulated Wires and Cables |
| UL 1277 | Electrical Power and Control Tray Cables |
| UL 1685 | Vertical-Tray Fire Propagation and Smoke Release Test |
| ICEA S-58-679 | Control Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE, 4-ORANGE) |
| ICEA S-95-658 (NEMA WC70) | Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy |
Southwire 59337599 Applications
- Wet and dry areas, in conduits, ducts, troughs and cable trays.
- Direct burial, and aerial runs supported by a messenger.
- Exposed runs (TC-ER) per NEC 336.10.
- Class I, II and III, Division 2 per NEC Articles 501 and 502.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.