Southwire 59351202, Metal Clad Cable 14 AWG 4C Shielded Stranded Copper THHN 600 V
Description
Southwire 59351202 is an EZ-IN™ Mini-Split shielded Type MC cable with four 14 AWG 7-strand copper conductors, black, red, white and green, under an aluminum foil shield with an 18 AWG tinned copper drain wire, aluminum interlocked armor and a PVC jacket. It is rated 600 V, with conductors rated 90°C dry / 75°C wet.
Southwire 59351202 Technical Specs
Conductors and Insulation
| Conductor Size | 14 AWG |
|---|---|
| Number of Conductors | 4 |
| Strands | 7 |
| Conductor | Stranded class B compressed copper per ASTM B3 and ASTM B8 |
| Conductor Colors | Black, Red, White, Green |
| Insulation | Polyvinyl chloride (PVC) with nylon sheath |
| Insulation Thickness | 20 mils (0.51 mm) |
| Diameter Over Conductor | 0.070 in (0.18 cm) |
Shield, Armor and Jacket
| Shield | Aluminum foil with 18 AWG 19-strand tinned copper drain wire |
|---|---|
| Armor | Aluminum interlocked armor |
| Jacket | Polyvinyl chloride (PVC), sunlight resistant |
Dimensions and Weight
| Diameter Over Armor | 0.484 in (1.23 cm) |
|---|---|
| Jacket Thickness | 50 mils (1.27 mm) |
| Overall Diameter | 0.590 in (1.50 cm) |
| Approximate Weight | 175 lbs per 1,000 ft (260 kg/km) |
Ratings
| Voltage Rating | 600 V |
|---|---|
| Conductor Temperature Rating | 90°C dry / 75°C wet (Type THHN/THWN/TFN) |
| Location | Wet locations per NEC 330.10(11) |
Standards and Compliance
| ASTM B3 | Soft or Annealed Copper Wire |
|---|---|
| ASTM B8 | Concentric-Lay-Stranded Copper Conductors |
| ASTM B33 (drain wire) | Tin-Coated Soft or Annealed Copper Wire |
| UL 83 | Thermoplastic Insulated Wires and Cables |
| UL 1569 | Metal-Clad Cables |
| Buy American | Compliant with Buy American requirements, 49 U.S.C. § 5323(j), when ordered as “Made in the USA Only!” |
| Meets or Exceeds | Federal Specification A-A59544 (formerly J-C-30B); NFPA 70 (National Electrical Code), Article 330 |
Southwire 59351202 Applications
- Locations exposed to cinder fills, strong chlorides, caustic alkalis, or vapors of chlorine or hydrochloric acids.
- Fished or embedded in plaster.
- Installation without conduit.
- Concealed or exposed installations.
- Wet locations per NEC 330.10(11).
- Cable tray and approved raceways, or aerial installation on a messenger.
- Installs without anti-short bushings.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.