Southwire 59546802, EZ-QUICK™ MCHC Health Care Facility Modular Cable Assembly 12 AWG 2C + Grounds Stranded Copper Green Armor 120 in, 16 EA Carton
Description
Southwire 59546802 is a 120" EZ-QUICK™ MCHC health care facility modular cable assembly with 12 AWG stranded copper conductors in green aluminum interlocked armor and 10" leads, supplied as a pre-cut length with pre-stripped conductors and zinc die-cast snap-on connectors. Its black and white circuit conductors are insulated with polyvinyl chloride under a nylon sheath, Type THHN/THWN, and run with a green insulated copper ground and a full-sized bare aluminum grounding/bonding conductor.
Southwire 59546802 Technical Specs
Conductors
| Conductor Size | 12 AWG |
|---|---|
| Wire Make-Up | Two circuit conductors plus two grounding conductors |
| Conductor Colors | Black, White |
| Grounding Conductor | Green insulated copper, plus a full-sized bare 8000 series aluminum grounding/bonding conductor; armor and bare aluminum conductor form the equipment ground path |
| Conductor Material | Copper |
| Stranding | Stranded |
| Insulation | Polyvinyl chloride with nylon sheath, Type THHN/THWN |
Armor and Fittings
| Armor | Green aluminum interlocked armor |
|---|---|
| Armor Weight | As much as 45% lighter than steel MC cable |
| Assembly Length | 120" |
| Lead Length | 10" pre-stripped leads |
| End Fittings | Zinc die-cast snap-on connector |
| Binder | Binder tape bearing the print legend, wrapped around the assembly |
| Packaging | 16 EA carton |
Standards and Compliance
| Copper Conductors | ASTM B8 Concentric-Lay-Stranded Copper Conductors |
|---|---|
| Insulated Conductors | UL 83 Thermoplastic Insulated Wires and Cables |
| Metal-Clad Cable | UL 1569 Metal-Clad Cables |
| Firestop Fire Tests | UL 1479 Standard for Safety Fire Tests of Penetration Firestops |
| Vertical-Tray Fire Test | UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test |
| Meets or Exceeds | Federal Specification A-A59544 (formerly J-C-30B); NFPA 70 (National Electrical Code), Article 330; Metal-Clad Cable (PJAZ) product category |
| Chemical Limits | REACH/RoHS-2 (Chemical Limit) compliant |
| Anti-Short Bushings | Not required for use with MC cable per the NEC and UL |
Southwire 59546802 Applications
- Branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings.
- Concealed or exposed installations, including runs fished or embedded in plaster.
- Installation in cable tray and approved raceways.
- Environmental air-handling spaces per NEC 300.22 (C).
- Places of assembly per NEC 518.4 and theaters per NEC 520.5.
- Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2).
- Class I Div. 2, Class II Div 2 and Class III Div. 1.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.