Southwire 59548099, Instrumentation Cable 18 AWG 4 Pair Copper 600V Black
Description
Southwire 59548099 is an 18 AWG instrumentation cable built from 4 twisted pairs (8 conductors) of 7-strand Class B tinned copper. It has 100% coverage aluminum/polyester foil shielding with tinned copper drain wires. The jacket is black sunlight, oil and moisture resistant thermoplastic chlorinated polyethylene (CPE). The cable is rated 600V and -30°C to 90°C wet or dry.
Rated for Class I Div II. Installations as outlined in NEC Article 336.
Southwire 59548099 Technical Specs
Conductors
| Conductor Size | 18 AWG |
|---|---|
| Number of Pairs | 4 |
| Total Conductors | 8 |
| Stranding | 7-strand, Class B |
| Conductor Material | Tinned copper |
| Conductor Color Code | Black and white, with an alpha-numeric print on each pair |
| Insulation | Flame-retardant ethylene propylene rubber (EPR) |
| Insulation Thickness | 30 mils (0.76 mm) |
| Diameter Over Conductor | 0.045 in (0.11 cm) |
Shielding and Jacket
| Shielding | Aluminum/polyester foil shielding at 100% coverage, with tinned copper drain wires |
|---|---|
| Drain Wires | Tinned copper |
| Binder | Mylar binder |
| Rip Cord | Under the jacket, for ease of removal |
| Jacket | Black sunlight, oil and moisture resistant thermoplastic chlorinated polyethylene (CPE) |
Dimensions and Weight
| Approximate Outside Diameter | 0.658 in (1.67 cm) |
|---|---|
| Jacket Thickness | 60 mils (1.52 mm) |
| Approximate Weight | 175 lbs/1000 ft (260 kg/km) |
| Minimum Bend Radius | 3.9 in (9.91 cm) |
Ratings and Standards
| Voltage Rating | 600V |
|---|---|
| Temperature Range | -30°C to 90°C wet or dry |
| DC Resistance at 25°C, per Conductor | 6.669 ohms/1000 ft |
| Standards | ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire; UL 44 Thermoset-Insulated Wires and Cables; UL 1277 Electrical Power and Control Tray Cables; UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test; ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables; IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test; EPA 40 CFR, Part 26, Subpart C heavy metals per Table 1, TCLP method |
Southwire 59548099 Applications
- Process control and instrumentation service.
- Control circuits that operate and interconnect protective and signaling devices.
- General use in manufacturing plants and industrial or commercial distribution systems.
- Cable trays, raceways and conduit, aerial runs supported by a messenger, and direct burial.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.