Southwire 61266225, Medium Voltage Cable 2 AWG 1C Aluminum 15 kV 100% TRXLP 10x14CN
Description
Southwire 61266225 is a single-conductor medium voltage cable in the 15kV HI-DRI Primary UD TRXLP Cable line, built on a 2 AWG, 7-strand moisture blocked unilay compressed stranded 1350-H16/26 aluminum phase conductor. It carries 175 mils of tree-retardant cross-linked polyethylene (TRXLP) insulation at a 100% insulation level, between semi-conducting strand and insulation shields. A concentric neutral of bare copper wires (10x14CN) is applied under a sunlight resistant, -40°C rated linear low density polyethylene jacket.
Southwire 61266225 Technical Specs
Conductor
| Conductor Size | 2 AWG |
|---|---|
| Number of Conductors | 1 |
| Stranding | 7 strands |
| Conductor | Moisture blocked unilay compressed stranded 1350-H16/26 aluminum |
| Strand Shield | Semi-conducting cross-linked polyethylene |
Insulation and Shielding
| Insulation | Tree-retardant cross-linked polyethylene (TRXLP) |
|---|---|
| Insulation Thickness | 175 mils (4.45 mm) |
| Insulation Level | 100% |
| Insulation Shield | Semi-conducting cross-linked polyethylene |
Neutral and Jacket
| Concentric Neutral | Bare copper wires, 10x14CN |
|---|---|
| Jacket | Insulating linear low density polyethylene; sunlight resistant, -40°C rated |
| Jacket Marking | Surface print, with the lightning bolt symbol for supply cables indented |
Dimensions and Weight
| Nominal Outside Diameter | 981 mils (24.92 mm) |
|---|---|
| Nominal Total Weight | 476 lbs/1000 ft (709 kg/km) |
Ratings
| Voltage | 15 kV; for use at 15,000 volts or less |
|---|---|
| Conductor Temperature | Not to exceed 90°C, normal operation |
Standards
Meets or exceeds the following specifications:
| ASTM B231 | Aluminum 1350 Conductors, Concentric-Lay-Stranded |
|---|---|
| ASTM B609 | Aluminum 1350 Round Wire, Annealed and Intermediate Tempers, for Electrical Purposes |
| ASTM B3 | Soft Annealed Copper Wire |
| Other Documents | ICEA S-94-649, AEIC CS-8, RUS U-1 |
Southwire 61266225 Applications
- Intended predominantly for primary underground distribution in conduit systems.
- Wet or dry locations, direct burial and underground duct, and installations exposed to sunlight.