Southwire 61349032, Bare Aluminum Conductor ACSS/MA2 1113 KCMIL 54/19 FINCH
Description
Southwire 61349032 is an ACSS bare overhead conductor in 1113 KCMIL, codeword FINCH. It is built from 54 strands of aluminum 1350-O wire in the fully annealed (soft) temper, stranded in two or more layers around a steel core of 19 wires. Nominal outside diameter is 1292 mils and nominal total weight is 1430 lbs per 1000 ft.
Southwire 61349032 Key Features
- Because of that soft temper, the steel core carries most or all of the conductor's mechanical load.
- Corrosion protection on the steel core wires is a zinc-5% aluminum-mischmetal alloy coating.
- Corrosion protection should suit the environment the conductor will be exposed to.
Southwire 61349032 Technical Specs
Conductor
| Codeword | FINCH |
|---|---|
| Conductor Type | ACSS (Aluminum Conductor, Steel Supported) |
| Southwire Designation | 1113-54/19 ACSS/MA2/63% FINCH |
| Conductor Size | 1113 KCMIL |
| Stranding (Aluminum/Steel) | 54/19 |
| Aluminum Wire | 1350-O, fully annealed (soft) temper |
| Core Designation | MA2 |
Dimensions and Weight
| Nominal Outside Diameter | 1292 mils (32.83 mm) |
|---|---|
| Nominal Total Weight | 1430 lbs/1000 ft (2128 kg/km) |
Standards
Its ACSS conductor meets or exceeds the following ASTM specifications.
| ASTM B500 | Metallic Coated Stranded Steel Core for Use in Overhead Electrical Conductors |
|---|---|
| ASTM B609 | Aluminum 1350 Round Wire, Annealed and Intermediate Tempers, for Electrical Purposes |
| ASTM B802 | Zinc-5% Aluminum-Mischmetal Alloy-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR) |
| ASTM B803 | High-Strength Zinc-5% Aluminum Mischmetal Alloy-Coated Steel Core Wire for Use in Overhead Electrical Conductors |
| ASTM B856 | Concentric-Lay-Stranded Aluminum Conductors, Coated Steel Supported (ACSS) |
| ASTM B958 | Extra-High-Strength and Ultra-High-Strength Class A Zinc-5% Aluminum-Mischmetal Alloy-Coated Steel Core Wire for Use in Overhead Electrical Conductors |
Southwire 61349032 Applications
- Overhead distribution and transmission lines.
- It operates continuously at elevated temperatures up to 250°C without loss of strength.
- It sags less than a comparable ACSR under electrical loadings, and its final sags are not affected by long-term creep of the aluminum.
- Self-damping is claimed for the conductor when it is prestretched during installation.
- Reconductoring that needs increased current at existing tensions and clearances, new lines where reduced sag lets structures be economized, new lines requiring high emergency loadings, and lines where aeolian vibration is a problem.