Southwire 61371601, Medium Voltage Cable 750 KCMIL 1C Aluminum 25 kV 100% TRXLP 24x12CN
Description
Southwire 61371601 is a single-conductor medium voltage cable in the 25kV HI-DRI Primary UD TRXLP Cable line, built on a 750 KCMIL, 61-strand moisture blocked reverse lay compressed stranded 1350-H16/26 aluminum phase conductor. It carries 260 mils of tree-retardant cross-linked polyethylene (TRXLP) insulation at a 100% insulation level, between semi-conducting strand and insulation shields. A concentric neutral of bare copper wires (24x12CN) is applied under a sunlight resistant, -40°C rated linear low density polyethylene jacket, which carries red extruded stripes.
Southwire 61371601 Technical Specs
Conductor
| Conductor Size | 750 KCMIL |
|---|---|
| Number of Conductors | 1 |
| Stranding | 61 strands |
| Conductor | Moisture blocked reverse lay compressed stranded 1350-H16/26 aluminum |
| Strand Shield | Semi-conducting cross-linked polyethylene |
Insulation and Shielding
| Insulation | Tree-retardant cross-linked polyethylene (TRXLP) |
|---|---|
| Insulation Thickness | 260 mils (6.60 mm) |
| Insulation Level | 100% |
| Insulation Shield | Semi-conducting cross-linked polyethylene |
Neutral and Jacket
| Concentric Neutral | Bare copper wires, 24x12CN |
|---|---|
| Jacket | Insulating linear low density polyethylene; sunlight resistant, -40°C rated |
| Jacket Marking | Surface print, with the lightning bolt symbol for supply cables indented; red extruded stripes |
Dimensions and Weight
| Nominal Outside Diameter | 1,963 mils (49.88 mm) |
|---|---|
| Nominal Total Weight | 2,172 lbs/1000 ft (3,232 kg/km) |
Ratings
| Voltage | 25 kV; for use at 25,000 volts or less |
|---|---|
| Conductor Temperature | Not to exceed 90°C, normal operation |
Standards
Meets or exceeds the following specifications:
| ASTM B231 | Aluminum 1350 Conductors, Concentric-Lay-Stranded |
|---|---|
| ASTM B609 | Aluminum 1350 Round Wire, Annealed and Intermediate Tempers, for Electrical Purposes |
| ASTM B3 | Soft Annealed Copper Wire |
| Other Documents | ICEA S-94-649, AEIC CS-8, RUS U-1 |
Southwire 61371601 Applications
- Intended predominantly for primary underground distribution in conduit systems.
- Wet or dry locations, direct burial and underground duct, and installations exposed to sunlight.