Southwire 61613232, Medium Voltage Cable 1/0 AWG 1C Aluminum 15 kV 133% EPR 16x14CN
Description
Southwire 61613232 is a single-conductor medium voltage cable in the 15kV Primary UD EPR Cable line, built on a 1/0 AWG, 19-strand moisture blocked unilay compressed stranded 1350-H16/26 aluminum phase conductor. It carries 220 mils of ethylene propylene rubber (EPR) insulation at a 133% insulation level, between semi-conducting strand and insulation shields. A concentric neutral of bare copper wires (16x14CN) is applied under a sunlight resistant, -40°C rated linear low density polyethylene jacket, which carries red extruded stripes.
Southwire 61613232 Technical Specs
Conductor
| Conductor Size | 1/0 AWG |
|---|---|
| Number of Conductors | 1 |
| Stranding | 19 strands |
| Conductor | Moisture blocked unilay compressed stranded 1350-H16/26 aluminum |
| Strand Shield | Semi-conducting cross-linked polyethylene |
Insulation and Shielding
| Insulation | Ethylene propylene rubber (EPR) |
|---|---|
| Insulation Thickness | 220 mils (5.59 mm) |
| Insulation Level | 133% |
| Insulation Shield | Semi-conducting cross-linked polyethylene |
Neutral and Jacket
| Concentric Neutral | Bare copper wires, 16x14CN |
|---|---|
| Jacket | Insulating linear low density polyethylene; sunlight resistant, -40°C rated |
| Jacket Marking | Surface print, with the lightning bolt symbol for supply cables indented; red extruded stripes |
Dimensions and Weight
| Nominal Outside Diameter | 1,140 mils (28.96 mm) |
|---|---|
| Nominal Total Weight | 734 lbs/1000 ft (1,092 kg/km) |
Ratings
| Voltage | 15 kV; for use at 15,000 volts or less |
|---|---|
| Conductor Temperature | Not to exceed 105°C, normal operation |
Standards
Meets or exceeds the following specifications:
| ASTM B231 | Aluminum 1350 Conductors, Concentric-Lay-Stranded |
|---|---|
| ASTM B609 | Aluminum 1350 Round Wire, Annealed and Intermediate Tempers, for Electrical Purposes |
| ASTM B3 | Soft Annealed Copper Wire |
| Other Documents | ICEA S-94-649, AEIC CS-8, RUS U-1 |
Southwire 61613232 Applications
- Intended predominantly for primary underground distribution in conduit systems.
- Wet or dry locations, direct burial and underground duct, and installations exposed to sunlight.
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.