Southwire 61887401, Medium Voltage Cable 4/0 AWG 1C Aluminum 15 kV 175 mil TRXLP 10x12CN Super Smooth
Description
Southwire 61887401 is a HI-DRI Primary UD TRXLP Cable rated 15 kV: a single-conductor medium voltage cable built on a 4/0 AWG, 19-strand moisture blocked unilay compressed stranded 1350-H16/26 aluminum phase conductor. Its 175 mils of tree-retardant cross-linked polyethylene insulation, at a 100% insulation level, sit between a semi-conducting cross-linked polyethylene strand shield and insulation shield. The strand shield is a Super Smooth conductor shield. A concentric neutral of bare copper wires (10x12CN) lies under a sunlight resistant, -40°C rated linear low density polyethylene jacket with red extruded stripes.
Southwire 61887401 Technical Specs
Conductor
| Conductor Size | 4/0 AWG |
|---|---|
| Number of Conductors | 1 |
| Strands | 19 |
| Conductor | Moisture blocked unilay compressed stranded 1350-H16/26 aluminum |
| Strand Shield | Semi-conducting cross-linked polyethylene; Super Smooth conductor shield |
Insulation and Shielding
| Insulation | Tree-retardant cross-linked polyethylene (TRXLP) |
|---|---|
| Insulation Thickness | 175 mils (4.45 mm) |
| Insulation Level | 100% |
| Insulation Shield | Semi-conducting cross-linked polyethylene |
Neutral and Jacket
| Concentric Neutral | Bare copper wires, 10x12CN |
|---|---|
| Jacket | Insulating linear low density polyethylene; sunlight resistant, -40°C rated |
| Jacket Identification | Surface print; lightning bolt symbol for supply cables indented in the jacket; red extruded stripes |
Dimensions and Weight
| Nominal Outside Diameter | 1,229 mils (31.23 mm) |
|---|---|
| Nominal Total Weight | 816 lbs/1000 ft (1,214 kg/km) |
Ratings
| Voltage | 15 kV; for use at 15,000 volts or less |
|---|---|
| Conductor Temperature | Not to exceed 90°C, normal operation |
Standards Met or Exceeded
| ASTM | ASTM B231, ASTM B609, ASTM B3 |
|---|---|
| Other Documents | ICEA S-94-649, AEIC CS-8, RUS U-1 |
Southwire 61887401 Applications
- Used predominantly for primary underground distribution in conduit systems.
- Wet or dry locations, direct burial and underground duct, including installations exposed to sunlight.
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.