Southwire 62583301, Substation Cable 14 AWG 4C Copper XHHW-2 CPE Type TC 600 V Black
Description
Southwire 62583301 is a 600 V UL Type TC substation control cable with four 14 AWG conductors of 7-strand class B compressed bare copper. Each conductor has flame retardant cross-linked polyethylene (FR-XLPE) insulation, 30 mils thick, carrying the XHHW-2 designation. The cable is finished in a black thermoset chlorinated polyethylene (CPE) jacket, with a rip cord for jacket removal. Conductors are color coded to ICEA S-58-679 Method 1 Table 2. Conductor temperature limits are 90°C continuous in wet and dry locations, 130°C for emergency overload and 250°C under short-circuit conditions.
Southwire 62583301 Technical Specs
Construction
| Number of Conductors | 4 |
|---|---|
| Conductor Size | 14 AWG |
| Strands per Conductor | 7 |
| Conductor | Class B compressed bare copper per ASTM B3 and ASTM B8 |
| Insulation | Flame retardant cross-linked polyethylene (FR-XLPE) |
| Insulation Designation | XHHW-2 |
| Insulation Thickness | 30 mils (0.76 mm) |
| Filler | Polypropylene |
| Conductor Identification | ICEA S-58-679 Method 1 Table 2 |
| Conductor Colors | BLACK/RED/BLUE/ORANGE |
| Rip Cord | Yes |
| Jacket | Thermoset chlorinated polyethylene (CPE) |
| Jacket Color | Black |
Dimensions and Weight
| Nominal Outside Diameter | 420 mils (10.69 mm) |
|---|---|
| Nominal Weight | 113 lbs/1000 ft (169 kg/km) |
Ratings
| Voltage Rating | 600 V |
|---|---|
| UL Type | TC |
Standards
| ASTM B3 | Soft or Annealed Copper Wire |
|---|---|
| ASTM B8 | Concentric-Lay-Stranded Copper Conductors |
| UL 1277 | Electrical Power and Control Tray Cables |
| UL 1685 | FT4 Vertical-Tray Fire Propagation and Smoke Release Test |
| ICEA S-58-679 | Control Cable Conductor Identification |
| ICEA S-73-532 | Control, Thermocouple Extension and Instrumentation Cables |
| ICEA S-95-658 (NEMA WC70) | Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy |
| IEEE 1202 | FT4 Vertical Tray Flame Test (70,000 Btu/hr) |
| ICEA T-29-520 | Vertical Tray Flame Test (210,000 Btu/hr) |
| VW-1 | Vertical-Wire Flame Test |
Southwire 62583301 Applications
- Wet and dry locations.
- Installation in conduits, ducts, troughs and trays.
- Direct burial.
- Aerial runs supported by a messenger.