Southwire 63949202, NM-B Cable 8 AWG 3C Copper with Ground
Description
Southwire 63949202 is an 8 AWG copper Type NM-B nonmetallic-sheathed cable, from Southwire's Romex Brand SIMpull line. It carries 3 insulated conductors (black, white and red) and a 10 AWG bare copper ground. The 7-strand Class B compressed copper conductors are PVC insulated under a nylon sheath, with a kraft paper binder inside the PVC jacket. The voltage rating is 600 volts for NM-B cable.
Southwire 63949202 Technical Specs
Construction
| Conductor Size | 8 AWG |
|---|---|
| Number of Conductors | 3 |
| Conductor Material | Bare copper per ASTM B3 |
| Stranding | 7 strands, Class B compressed per ASTM B8 |
| Conductor Colours | Black, White, Red |
| Ground | 10 AWG solid soft drawn bare copper with kraft paper wrap |
| Insulation | Polyvinyl chloride (PVC) with nylon sheath |
| Binder | Kraft paper |
| Jacket | PVC, utilizing SIMpull Technology |
Dimensions and Weight
| Diameter Over Conductor | 0.141 in (0.36 cm) |
|---|---|
| Insulation Thickness | 30 mils (0.76 mm) |
| Jacket Thickness | 30 mils (0.76 mm) |
| Approx. Overall Diameter | 0.585 in (1.49 cm) |
| Copper Content Weight | 185 lbs/1000 ft (275 kg/km) |
| Approx. Total Weight | 260 lbs/1000 ft (387 kg/km) |
Ratings
| Voltage | 600 volts |
|---|---|
| Conductor Insulation | Rated 90°C, as required by the NEC and UL 719 for terminations in lighting fixtures |
| Ampacity | Limited to that for 60°C conductors |
Standards
| ASTM B3 | Soft or Annealed Copper Wire |
|---|---|
| ASTM B8 | Concentric-Lay-Stranded Copper Conductors |
| UL 719 | Nonmetallic-Sheathed Cables |
| Federal Specification | A-A-59544 |
| NOM-063-SCFI | Electrical Products – Conductors – Safety Requirements |
| RoHS-2 | European Directive 2011/65/EU |
Southwire 63949202 Applications
- Used for both exposed and concealed work in dry locations, as specified in the National Electrical Code (NEC).
- NM-B cable is primarily used in residential wiring, as branch circuits for outlets, switches and other loads.
- Can be run in the air voids of masonry block or tile walls, where those walls are not wet or damp locations.
- Install it only as a complete cable: The individual conductors are not listed or marked as THHN conductors (or any other NEC recognized conductor type) and may not be installed apart from the cable, while conductors routed inside panelboards and boxes for termination count as part of it.