Southwire 63950002, NM-B Cable 6 AWG 3C Copper with Ground
Description
Southwire 63950002 is a 6 AWG copper Type NM-B nonmetallic-sheathed cable, from Southwire's Romex Brand SIMpull line. It carries 3 insulated conductors (black, white and red) and a 10 AWG bare copper ground. The 7-strand Class B compressed copper conductors are PVC insulated under a nylon sheath, with a kraft paper binder inside the PVC jacket. The voltage rating is 600 volts for NM-B cable.
Southwire 63950002 Technical Specs
Construction
| Conductor Size | 6 AWG |
|---|---|
| Number of Conductors | 3 |
| Conductor Material | Bare copper per ASTM B3 |
| Stranding | 7 strands, Class B compressed per ASTM B8 |
| Conductor Colours | Black, White, Red |
| Ground | 10 AWG solid soft drawn bare copper with kraft paper wrap |
| Insulation | Polyvinyl chloride (PVC) with nylon sheath |
| Binder | Kraft paper |
| Jacket | PVC, utilizing SIMpull Technology |
Dimensions and Weight
| Diameter Over Conductor | 0.177 in (0.45 cm) |
|---|---|
| Insulation Thickness | 30 mils (0.76 mm) |
| Jacket Thickness | 30 mils (0.76 mm) |
| Approx. Overall Diameter | 0.672 in (1.71 cm) |
| Copper Content Weight | 276 lbs/1000 ft (411 kg/km) |
| Approx. Total Weight | 365 lbs/1000 ft (543 kg/km) |
Ratings
| Voltage | 600 volts |
|---|---|
| Conductor Insulation | Rated 90°C, as required by the NEC and UL 719 for terminations in lighting fixtures |
| Ampacity | Limited to that for 60°C conductors |
Standards
| ASTM B3 | Soft or Annealed Copper Wire |
|---|---|
| ASTM B8 | Concentric-Lay-Stranded Copper Conductors |
| UL 719 | Nonmetallic-Sheathed Cables |
| Federal Specification | A-A-59544 |
| NOM-063-SCFI | Electrical Products – Conductors – Safety Requirements |
| RoHS-2 | European Directive 2011/65/EU |
Southwire 63950002 Applications
- Used for both exposed and concealed work in dry locations, as specified in the National Electrical Code (NEC).
- NM-B cable is primarily used in residential wiring, as branch circuits for outlets, switches and other loads.
- Can be run in the air voids of masonry block or tile walls, where those walls are not wet or damp locations.
- Install it only as a complete cable: The individual conductors are not listed or marked as THHN conductors (or any other NEC recognized conductor type) and may not be installed apart from the cable, while conductors routed inside panelboards and boxes for termination count as part of it.
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.