Southwire 64085399, Armored Cable 8 AWG 3C Copper 1 kV Black
Southwire · MPN 64085399
Description
Southwire 64085399 is an 8 AWG three-conductor Type TECK 90 armored power cable rated 1 kV. Its three 7-strand copper conductors carry 45 mils of cross-linked polyethylene (XLPE) insulation, color-coded black, red and blue, and an uninsulated grounding conductor runs with them. A black PVC inner jacket, aluminum interlocked armor (AIA) and a black PVC outer jacket complete the cable.
Southwire 64085399 Technical Specs
Conductors & Insulation
| Conductor Size | 8 AWG |
|---|---|
| Number of Conductors | 3 |
| Strands per Conductor | 7 |
| Conductor | Class B compressed stranded copper per ASTM B3 and B8 |
| Conductor Identification | Black, red, blue |
| Insulation | Cross-linked polyethylene (XLPE) |
| Insulation Thickness | 45 mils (1.14 mm) |
| Diameter Over Conductor | 0.141 in (0.36 cm) |
Grounding, Armor & Jacket
| Grounding Conductor | Uninsulated grounding conductor, Class B stranded |
|---|---|
| Binder | Mylar tape |
| Inner Jacket | Black PVC |
| Inner Jacket Thickness | 50 mils (1.27 mm) |
| Armor | Aluminum interlocked armor (AIA) |
| Diameter Over Armor | 0.846 in (2.15 cm) |
| Outer Jacket | Black polyvinyl chloride (PVC) |
| Jacket Thickness | 55 mils (1.40 mm) |
Dimensions & Weight
| Approximate Outside Diameter | 0.956 in (2.43 cm) |
|---|---|
| Approximate Weight | 490 lbs/1000 ft (729 kg/km) |
| Maximum Pull Tension | 396 lbs (179.62 kg) |
| Minimum Bend Radius | 6.7 in (17.02 cm) |
Ratings & Compliance
| Voltage Rating | 1 kV |
|---|---|
| Type Designation | Type TECK 90 |
| Operating Temperatures | 90°C maximum continuous operating |
| Cold Bend | -40°C (CSA cold bend and impact) |
| Minimum Installation Temperature | -40°C |
| Sunlight Resistance | Sunlight resistant |
| Standards | ASTM B3 Soft or Annealed Copper Wire; ASTM B8 Concentric-Lay-Stranded Copper Conductors; UL 1569 Metal-Clad Cables; CSA C22.2 No. 174; CSA C22.2 No. 131 Type TECK 90 Cable; CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating; CSA AG14 - Acid Gas Compliance; ICEA S-58-679 Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE); IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test |
Southwire 64085399 Applications
- Used for exposed or concealed wiring in wet or dry locations.
- Can be run in ventilated, non-ventilated and ladder-type cable troughs and in ventilated flexible cableway in wet, dry or classified locations, or buried directly.
- Control, lighting and power circuits in pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.