Southwire 64146899, Armored Cable 12 AWG 3C Copper XHHW-2 600 V Black
Southwire · MPN 64146899
Description
Southwire 64146899 is a 12 AWG three-conductor armored power cable rated 600 V. Its three 7-strand compressed copper conductors carry 30 mils of XHHW-2 cross-linked polyethylene (XLPE) insulation, and three 16 AWG bare copper grounding conductors run with them. ARMOR-X® continuous corrugated welded armor and a black SOLONON® LSZH-TP outer jacket complete the cable.
Southwire 64146899 Technical Specs
Conductors & Insulation
| Conductor Size | 12 AWG |
|---|---|
| Number of Conductors | 3 |
| Strands per Conductor | 7 |
| Conductor | Class B compressed stranded copper, 7 strands |
| Conductor Identification | Black-1-One, Red-2-Two, Blue-3-Three |
| Insulation | Cross-linked polyethylene (XLPE), Type XHHW-2 |
| Insulation Thickness | 30 mils (0.76 mm) |
Grounding, Armor & Jacket
| Grounding Conductor | Three 16 AWG bare copper grounding conductors, Class B compressed stranded |
|---|---|
| Filler | Polypropylene |
| Armor | ARMOR-X® continuous corrugated welded armor |
| Diameter Over Armor | 0.570 in (1.45 cm) |
| Outer Jacket | Black thermoplastic SOLONON® low smoke zero halogen (LSZH-TP) |
| Jacket Thickness | 50 mils (1.27 mm) |
Dimensions & Weight
| Approximate Outside Diameter | 0.670 in (1.70 cm) |
|---|---|
| Approximate Weight | 233 lbs/1000 ft (347 kg/km) |
| Copper Weight | 85 lbs/1000 ft (126 kg/km) |
| Minimum Bend Radius | 4.7 in (11.94 cm) |
Electrical
| DC Resistance at 25°C | 1.662 ohms/1000 ft |
|---|---|
| AC Resistance at 75°C | 2.002 ohms/1000 ft |
| Allowable Ampacity, Raceway 75°C | 25 |
| Allowable Ampacity, Raceway 90°C | 30 |
Ratings & Compliance
| Voltage Rating | 600 V |
|---|---|
| Operating Temperatures | 90°C normal operation; 130°C emergency overload; 250°C short circuit |
| Cold Bend | -50°C |
| Location Rating | Class I, II, and III, Division 1 and 2 per NEC Article 501, 502, and 503 |
| Standards | ASTM B3 Soft or Annealed Copper Wire; ASTM B8 Concentric-Lay-Stranded Copper Conductors; UL 44 Thermoset-Insulated Wires and Cables; UL 1309 Marine Shipboard Cable; UL 1569 Metal-Clad Cables; UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test; ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2; ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables; ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy; IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test |
Southwire 64146899 Applications
- Wet and dry areas, conduits, ducts, troughs, trays and direct burial, as well as aerial runs supported by a messenger.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.