Southwire 64657399, Medium Voltage Cable 4/0 AWG Copper 8 kV Black PVC
Description
Southwire 64657399 is an 8 kV shielded medium voltage power cable with a single 4/0 AWG copper conductor of 19 strands under a black SIMpull PVC jacket. The conductor carries 140 mils of NL-EPR insulation at the 133% insulation level, between semi-conducting conductor and insulation shields, with a 5 mil copper tape shield. Conductor temperature rating is 105°C for normal operation.
Southwire 64657399 Technical Specs
Construction
| Number of Conductors | 1 |
|---|---|
| Conductor Size | 4/0 AWG |
| Strands | 19 |
| Conductor | Class B compressed stranded bare copper per ASTM B3 and ASTM B8 |
| Conductor Shield | Semi-conducting cross-linked copolymer |
| Insulation | No Lead Ethylene Propylene Rubber (NL-EPR), 133% insulation level |
| Insulation Shield | Strippable semi-conducting cross-linked copolymer |
| Metallic Shield | Helically wrapped 5 mil copper tape with 25% overlap |
| Jacket | SIMpull Polyvinyl Chloride (PVC) |
| Jacket Color | Black |
Dimensions and Weight
| Diameter Over Conductor | 0.512 in (1.30 cm) |
|---|---|
| Diameter Over Insulation | 0.816 in (2.07 cm) |
| Insulation Thickness | 140 mils (3.56 mm) |
| Diameter Over Shield | 0.876 in (2.23 cm) |
| Jacket Thickness | 80 mils (2.03 mm) |
| Overall Diameter (approx.) | 1.056 in (2.68 cm) |
| Weight (approx.) | 1078 lbs/1000 ft (1604 kg/km) |
Installation Limits
| Maximum Pulling Tension | 1692 lbs (767.48 kg) |
|---|---|
| Minimum Bending Radius | 12.6 in (32.00 cm) |
| Maximum Sidewall Pressure | 1000 lb/ft |
| Coefficient of Friction | 0.2 (SIM technology jacket) |
| Conduit Pulling | Installs in conduit without lubrication |
Ratings
| Voltage Class | 8 kV |
|---|---|
| Insulation Level | 133% |
| Conductor Temperature | 105°C normal operation; 140°C emergency overload; 250°C short circuit |
Standards
| ASTM B3 | Soft or Annealed Copper Wire |
|---|---|
| ASTM B8 | Concentric-Lay-Stranded Copper Conductors |
| UL 1072 | Medium-Voltage Power Cables |
| UL 1685 | FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger) |
| CSA C22.2 No.230 | Tray Cables - Rated TC-ER (1/0 AWG and Larger) |
| CSA C22.2 No. 2556 / UL 2556 | Cable Test Methods |
| CSA C68.10 | Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV |
| ICEA S-93-639 (NEMA WC 74) | 5-46 KV Shielded Power Cable |
| ICEA S-97-682 | Standard for Shielded Utility Cable Rated for 5 - 46kV |
| IEEE 1202 | FT4 Flame Test (70,000) BTU/hr Vertical Tray Test (1/0 and Larger) |
| AEIC CS-8 | Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements) |
| Made in America | Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661 |
Southwire 64657399 Applications
- Wet and dry locations.
- Installation in conduits, ducts, troughs and trays.
- Direct burial when installed with a grounding conductor in close proximity that conforms to NEC section 311.36 and 250.4(A)(5).
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.