Southwire 64683599, Metal Clad Cable 1/0 AWG 4C with 2 Grounds Stranded Copper THHN 600 V
Description
Southwire 64683599 is an Armorlite® Type MC copper feeder cable with four 1/0 AWG stranded copper Type THHN/THWN conductors in black, red, blue and white, plus two insulated copper grounds, green and green-yellow, under aluminum interlocked armor. Rated 600 V; conductors are rated 90°C dry / 75°C wet.
Southwire 64683599 Technical Specs
Conductors and Insulation
| Conductor Size | 1/0 AWG |
|---|---|
| Number of Conductors | 4, plus two grounding conductors |
| Conductor | Class B compressed stranded copper per ASTM B3 and ASTM B8 |
| Strands | 19 |
| Conductor Colors | Black, Red, Blue, White |
| Insulation | Polyvinyl chloride with nylon sheath, Type THHN/THWN |
| Insulation Thickness | 60 mils (1.52 mm) |
| Diameter Over Conductor | 0.361 in (0.92 cm) |
Grounding and Armor
| Grounds | Two insulated copper grounds, green and green-yellow |
|---|---|
| Filler | Fillers as needed |
| Binder | Mylar tape |
| Armor | Aluminum interlocked armor |
Dimensions and Weight
| Diameter Over Armor | 1.677 in (4.26 cm) |
|---|---|
| Approximate Weight | 2377 lbs per 1,000 ft (3537 kg/km) |
Ratings
| Voltage Rating | 600 V |
|---|---|
| Conductor Temperature Rating | 90°C dry / 75°C wet, Type THHN/THWN |
Standards
| ASTM B3 | Soft or annealed copper wire |
|---|---|
| ASTM B8 | Concentric-lay-stranded copper conductors |
| UL 83 | Thermoplastic insulated wires and cables |
| UL 1569 | Metal-clad cables |
| UL 1479 | Fire tests of penetration firestops |
| UL 1685 FT4 | Vertical-tray fire propagation and smoke release test |
| IEEE 1202 FT4 | Flame test (70,000) BTU/hr vertical tray test |
| Buy American | Compliant with Buy American Requirements, found in 49 U.S.C. § 5323(j), when ordered as “Made in the USA Only!” |
| Federal Specification | Meets or exceeds A-A59544 (formerly J-C-30B) |
| NFPA 70 (NEC) | Meets or exceeds Article 330 |
Southwire 64683599 Applications
- Feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings.
- Fished or embedded in plaster.
- Concealed or exposed installations.
- Places of assembly per NEC 518.4 and theaters per NEC 520.5.
- Cable tray and approved raceways.
- Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) and 645.5(D)(2).
- Class I Div. 2, Class II Div. 2 and Class III Div. 1.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.