Southwire 64764002, Metal Clad Cable 12 AWG 2C with Ground Solid Copper THHN plus 16 AWG Signal Pair
Description
Southwire 64764002 is an MC AP-PCS Duo™ Type MC power and control/signal cable with two 12 AWG solid copper Type THHN/THWN power conductors in orange and gray, a 10 AWG bare aluminum grounding/bonding conductor and a 16 AWG Type TFN signal pair, under one aluminum interlocked armor. The armor and the bare aluminum conductor form the equipment ground path; the light blue jacket and the pink and purple singles belong to the signal pair. Conductors are rated 90°C dry.
Southwire 64764002 Technical Specs
Conductors and Insulation
| Conductor Size | 12 AWG |
|---|---|
| Power Conductors | 2, plus one grounding/bonding conductor |
| Conductor | Solid copper per ASTM B3 |
| Conductor Colors | Orange, Gray |
| Insulation | Polyvinyl chloride with nylon sheath, Type THHN/THWN |
| Insulation Thickness | 20 mils (0.51 mm) |
| Diameter Over Conductor | 0.080 in (0.20 cm) |
| Signal Pair | Two 16 AWG copper Type TFN insulated singles, pink and purple, under an overall light blue jacket |
Grounding and Armor
| Grounding | 10 AWG bare 8000 series aluminum grounding/bonding conductor per ASTM B800; armor and bare aluminum conductor form the equipment ground path |
|---|---|
| Binder | Mylar tape with print legend, wrapped around the assembly |
| Armor | Aluminum interlocked armor |
Dimensions and Weight
| Diameter Over Armor | 0.614 in (1.56 cm) |
|---|---|
| Approximate Weight | 139 lbs per 1,000 ft (207 kg/km) |
Ratings
| Conductor Temperature Rating | 90°C dry, Type THHN/THWN |
|---|---|
| Location | Dry, indoor locations only (unjacketed Type MC, NEC 330.10(A)(10)) |
Standards
| ASTM B3 | Soft or annealed copper wire |
|---|---|
| ASTM B8 | Concentric-lay-stranded copper conductors |
| ASTM B800 | 8000 series aluminum alloy wire |
| UL 83 | Thermoplastic insulated wires and cables |
| UL 1569 | Metal-clad cables |
| UL 1479 | Fire tests of penetration firestops |
| UL 1685 FT4 | Vertical-tray fire propagation and smoke release test |
| IEEE 1202 FT4 | Flame test (70,000) BTU/hr vertical tray test |
| Buy American | Compliant with Buy American Requirements, found in 49 U.S.C. § 5323(j), when ordered as “Made in the USA Only!” |
| Federal Specification | Meets or exceeds A-A59544 (formerly J-C-30B) |
| NFPA 70 (NEC) | Meets or exceeds Article 330 |
Southwire 64764002 Applications
- Branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings.
- Fished or embedded in plaster.
- Concealed or exposed installations.
- Environmental air-handling spaces per NEC 300.22(C).
- Places of assembly per NEC 518.4 and theaters per NEC 520.5.
- Cable tray and approved raceways.
- Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) and 645.5(D)(2).
- Class I Div. 2, Class II Div. 2 and Class III Div. 1.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.