Southwire 64878399, Armored Cable 2/0 AWG 3C Copper 35 kV Red
Southwire · MPN 64878399
Description
Southwire 64878399 is a 2/0 AWG three-conductor HVTECK medium-voltage armored power cable rated 35 kV at 133% insulation level. Each of its three 19-strand copper conductors carries 420 mils of NL-EPR with semi-conducting conductor and insulation shields and a 5 mil copper tape shield, and one 4 AWG bare copper grounding conductor runs with them. A PVC inner jacket, aluminum interlocked armor (AIA) and a red PVC outer jacket complete the cable.
Southwire 64878399 Technical Specs
Conductors & Insulation
| Conductor Size | 2/0 AWG |
|---|---|
| Number of Conductors | 3 |
| Strands per Conductor | 19 |
| Conductor | Class B compressed stranded bare copper per ASTM B3 and ASTM B8 |
| Insulation | No-lead ethylene propylene rubber (NL-EPR) |
| Insulation Thickness | 420 mils (10.67 mm) |
| Insulation Level | 133% |
| Diameter Over Conductor | 0.405 in (1.03 cm) |
| Diameter Over Insulation | 1.284 in (3.26 cm) |
Shielding
| Conductor Shield | Semi-conducting cross-linked copolymer |
|---|---|
| Insulation Shield | Strippable semi-conducting cross-linked copolymer |
| Metallic Shield | Helically wrapped 5 mil copper tape, 25% overlap |
| Diameter Over Shield | 1.344 in (3.41 cm) |
Grounding, Armor & Jacket
| Grounding Conductor | One 4 AWG bare copper grounding conductor, Class B compressed stranded |
|---|---|
| Filler | Non-hydroscoping, non-wicking interstice fillers |
| Binder | Polypropylene tape |
| Inner Jacket | PVC |
| Inner Jacket Thickness | 125 mils (3.18 mm) |
| Armor | Aluminum interlocked armor (AIA) |
| Diameter Over Armor | 3.566 in (9.06 cm) |
| Outer Jacket | Red polyvinyl chloride (PVC) |
| Jacket Thickness | 85 mils (2.16 mm) |
Dimensions & Weight
| Approximate Outside Diameter | 3.736 in (9.49 cm) |
|---|---|
| Approximate Weight | 6275 lbs/1000 ft (9338 kg/km) |
| Maximum Pull Tension | 3194 lbs (1448.77 kg) |
| Minimum Bend Radius | 26.2 in (66.55 cm) |
Ratings & Compliance
| Voltage Rating | 35 kV |
|---|---|
| Operating Temperatures | 105°C normal operation; 140°C emergency overload; 250°C short circuit |
| Cold Bend | -40°C (CSA LTGG, per C68.10, cold bend and impact) |
| Location Rating | HL rating per CSA HL |
| Maximum Sidewall Pressure | 1000 lbs/ft |
| Standards | ASTM B3 Soft or Annealed Copper Wire; ASTM B8 Concentric-Lay-Stranded Copper Conductors; CSA C22.2 No. 174; CSA C22.2 No. 2556 & No. 0.3 Wire and Cable Test Methods; CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV; CSA C68.3 Shielded & Concentric Neutral Power Cable - 5 to 46 kV; CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating; CSA HL rating; CSA SUN RES - for Sunlight Resistant rating; ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable; ICEA T-29-520 Flame Test (210,000 BTU/Hr); IEEE 383 Flame Test (70,000 btu); IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test; FT1 Flame Test (1,706 BTU/Hr nominal - Vertical Wire Flame Test); AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements) |
Southwire 64878399 Applications
- HVTECK is a CSA armored cable for industrial and commercial medium-voltage applications.
- Its construction is sunlight and moisture resistant, corona resistant, resistant to most chemical soils and acids, and flame retardant.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.