Southwire 64983499, Armored Cable 500 KCMIL 3C Copper 8 kV Orange
Southwire · MPN 64983499
Description
Southwire 64983499 is a 500 KCMIL three-conductor HVTECK armored cable rated 8 kV at a 133% insulation level, built on 37-strand bare copper conductors. Every conductor is covered by a semi-conducting shield, 140 mils of no-lead ethylene propylene rubber (NL-EPR), a strippable insulation shield and a 5 mil copper tape shield, and a #3 AWG bare copper grounding conductor is cabled with them. Over a PVC inner jacket come aluminum interlocked armor (AIA) and an orange PVC outer jacket.
Southwire 64983499 Technical Specs
Conductors & Insulation
| Conductor Size | 500 KCMIL |
|---|---|
| Number of Conductors | 3 |
| Strand Count | 37 |
| Conductor | Class B compressed stranded bare copper per ASTM B3 and ASTM B8 |
| Insulation | No-lead ethylene propylene rubber (NL-EPR) |
| Insulation Thickness | 140 mils (3.56 mm) |
| Conductor Colors | Black |
| Diameter Over Conductor | 0.789 in (2.00 cm) |
| Diameter Over Insulation | 1.092 in (2.77 cm) |
Shielding & Grounding
| Conductor Shield | Semi-conducting cross-linked copolymer |
|---|---|
| Insulation Shield | Strippable semi-conducting cross-linked copolymer |
| Metallic Shield | 5 mil copper tape, helically wrapped with 25% overlap |
| Diameter Over Shield | 1.152 in (2.93 cm) |
| Grounding Conductor | One #3 AWG, Class B compressed stranded bare copper |
Jacket & Armor
| Filler | Non-hygroscopic, non-wicking fillers in the interstices |
|---|---|
| Binder | Polypropylene tape |
| Inner Jacket | PVC |
| Inner Jacket Thickness | 125 mils (3.18 mm) |
| Armor | Aluminum interlocked armor (AIA) |
| Diameter Over Armor | 3.129 in (7.95 cm) |
| Outer Jacket | Orange polyvinyl chloride (PVC) |
| Jacket Thickness | 85 mils (2.16 mm) |
Dimensions & Weight
| Nominal Outside Diameter | 3.299 in (8.38 cm) |
|---|---|
| Approximate Weight | 8,123 lbs/1000 ft (12088 kg/km) |
| Maximum Pull Tension | 12,000 lbs (5443.10 kg) |
| Minimum Bend Radius | 23.1 in (58.67 cm) |
Ratings
| Voltage Rating | 8 kV |
|---|---|
| Insulation Level | 133% |
| Conductor Temperature | 105°C normal operation; 140°C emergency overload; 250°C short circuit |
| Maximum Sidewall Pressure | 1000 lbs/ft |
Standards
- ASTM B3 Soft or Annealed Copper Wire
- ASTM B8 Concentric-Lay-Stranded Copper Conductors
- CSA C22.2 No. 174
- CSA C22.2 No. 2556 & No. 0.3 Wire and Cable Test Methods
- CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV
- CSA C68.3 Shielded & Concentric Neutral Power Cable - 5 to 46 kV
- CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating
- CSA HL rating
- CSA SUN RES - for Sunlight Resistant rating
- ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
- ICEA T-29-520 Flame Test (210,000 BTU/Hr)
- IEEE 383 Flame Test (70,000 btu)
- IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test (1/0 and Larger)
- FT1 Flame Test (1,706 BTU/Hr nominal - Vertical Wire Flame Test)
- AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
This 8kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications, rated FT4, -40°C and HL, with sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids, and flame retardance.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.