Southwire 66258003, Substation Cable 12 AWG 3C Copper XHHW Shielded PVC Jacket 600 V Black
Description
Southwire 66258003 is a 600 V substation control cable with three 12 AWG stranded bare copper conductors, flame retardant cross linked polyethylene (FR-XLPE) insulation with an XHHW designation and a black polyvinyl chloride (PVC) jacket. The cable carries a 5 mil tape shield. The conductors operate continuously at up to 90°C in wet and dry locations, 130°C under emergency overload and 250°C under short circuit conditions.
Southwire 66258003 Technical Specs
Conductors
| Conductor Size | 12 AWG |
|---|---|
| Number of Conductors | 3 |
| Strands per Conductor | 7 |
| Conductor Material | Bare copper, class B compressed stranding |
| Conductor Identification | ICEA S-58-679 Method 1 Table 2 |
| Conductor Colors | Black, Red, Blue |
Insulation, Shield and Jacket
| Insulation | Flame retardant cross linked polyethylene (FR-XLPE) |
|---|---|
| Insulation Type | XHHW |
| Insulation Thickness | 30 mils (0.76 mm) |
| Shield | 5 mil tape shield |
| Filler | Polypropylene |
| Rip Cord | Yes, for jacket removal |
| Jacket | Black polyvinyl chloride (PVC) |
Electrical, Dimensions and Weight
| Voltage | 600 V |
|---|---|
| Nominal Outside Diameter | 448 mils (11.40 mm) |
| Nominal Total Weight | 164 lbs/1000 ft (244 kg/km) |
Standards
| ASTM B3 | Soft or Annealed Copper Wire |
|---|---|
| ASTM B8 | Concentric-Lay-Stranded Copper Conductors |
| UL 44 | Thermoset-Insulated Wires and Cables |
| UL 1277 | Electrical Power and Control Tray Cables |
| UL 1685 FT4 | Vertical-Tray Fire Propagation and Smoke Release Test |
| ICEA S-58-679 | Control Cable Conductor Identification |
| ICEA S-73-532 | Control, Thermocouple Extension and Instrumentation Cables |
| ICEA S-95-658 (NEMA WC70) | Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy |
| IEEE 1202 FT4 | Vertical Tray Flame Test (70,000 Btu/hr) |
| ICEA T-29-520 | Vertical Tray Flame Test (210,000 Btu/hr) |
| VW-1 | Vertical-Wire Flame Test |
Southwire 66258003 Applications
- Wet and dry locations.
- Installation in conduits, ducts and troughs.
- Cable tray runs.
- Direct burial.
- Aerial runs supported by a messenger.
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.