Southwire 66510799, Machine Flex Flexible Tray Cable 14 AWG 10C Copper TC-ER Black
Description
Southwire 66510799 is a 14 AWG, 10-conductor Machine Flex flexible power tray cable with Class K flexible stranded bare copper conductors, PVC-nylon insulation and a black thermoplastic elastomer (TPE) jacket. It carries the TC-ER, WTTC, ITC, PLTC and MTW type designations and is rated 600/1000V.
Southwire 66510799 Technical Specs
Construction
| Conductor Size | 14 AWG |
|---|---|
| Number of Conductors | 10 |
| Conductor | Class K flexible stranded bare annealed copper per ASTM B3, B172 and B174 |
| Strands per Conductor | 41 |
| Insulation | Polyvinyl chloride (PVC) with nylon layer, THHN |
| Conductor Identification | Numbered conductors per ICEA S-58-679 Method 4 |
| Grounding Conductor | One green ground with yellow stripe, THHN |
| Jacket | Black thermoplastic elastomer (TPE) |
| Type Designations | TC-ER, WTTC, ITC, PLTC, MTW |
Dimensions and Weight
| Diameter Over Conductor | 0.073 in (0.19 cm) |
|---|---|
| Insulation Thickness | 20 mils (0.51 mm) |
| Jacket Thickness | 65 mils (1.65 mm) |
| Approx. Overall Diameter | 0.601 in (1.53 cm) |
| Minimum Bend Radius | 2.4 in (6.10 cm) |
| Copper Weight | 127 lbs/1000 ft (189 kg/km) |
| Approx. Weight | 226 lbs/1000 ft (336 kg/km) |
Electrical and Thermal Ratings
| Voltage Rating | 600/1000V |
|---|---|
| Conductor Temperature | 75°C in wet locations and 90°C in dry locations; 130°C emergency overload; 150°C short circuit |
| Cold Impact | -40°C |
| AC Resistance at 75°C | 3.391 |
| Allowable Ampacity, Raceway, 75°C | 10 |
| Allowable Ampacity, Raceway, 90°C | 12 |
Standards
| ASTM B172 | Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors |
|---|---|
| ASTM B174 | Standard Specification for Bunch-Stranded Copper |
| UL 13 | Power-Limited Circuit Cables |
| UL 66 | Fixture Wire |
| UL 83 | Thermoplastic Insulated Wires and Cables |
| UL 1277 | TC-ER |
| UL 2250 | Instrumentation Tray Cable |
| UL 2277 | Type WTTC |
| CSA C22.2 No. 239 | Control and instrumentation cables |
| ICEA S-58-679 | Control Cable Conductor Identification Method 4 |
| ICEA S-95-658 (NEMA WC70) | Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy |
| IEEE 1202 FT4 | Flame Test (70,000) BTU/hr Vertical Tray Test |
| NFPA 79 | Electrical Standard for Industrial Machinery |
| CE/RoHS-2 | The CE Marking has been applied solely to express the conformance to the material restrictions identified in the RoHS-2 (2011/65/EU) Directive |
| Made in America | Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661 |
Southwire 66510799 Applications
- Industrial machinery wiring conforming to NFPA 79.
- Wet and dry areas: conduits, ducts, troughs, cable trays and direct burial.
- Exposed runs (TC-ER) per NEC 336.10.
- Class I, II, Division 2 per NEC Article 501 and 502.
- Power for CNC machines, grinding, cutting, metal forming, buffing and bottling equipment, conveyors, processing and packaging equipment, assembly lines and control panels.
- Food and beverage plants, oil sands, plant expansion, wind energy and data centers.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.