Southwire 66541499, Armored Cable 1 AWG 3C Copper 25 kV Red
Southwire · MPN 66541499
Description
Southwire 66541499 is a 1 AWG three-conductor HVTECK armored cable rated 25 kV at a 100% insulation level, built on 19-strand bare copper conductors. Every conductor is covered by a semi-conducting shield, 260 mils of tree-retardant cross-linked polyethylene (TRXLPE), a strippable insulation shield and a 5 mil copper tape shield, and a #6 AWG bare copper grounding conductor is cabled with them. Over a PVC inner jacket come aluminum interlocked armor (AIA) and a red PVC outer jacket.
Southwire 66541499 Technical Specs
Conductors & Insulation
| Conductor Size | 1 AWG |
|---|---|
| Number of Conductors | 3 |
| Strand Count | 19 |
| Conductor | Class B compressed stranded bare copper per ASTM B3 and ASTM B8 |
| Insulation | Tree-retardant cross-linked polyethylene (TRXLPE) |
| Insulation Thickness | 260 mils (6.60 mm) |
| Conductor Colors | Black |
| Diameter Over Conductor | 0.322 in (0.82 cm) |
| Diameter Over Insulation | 0.88 in (2.24 cm) |
Shielding & Grounding
| Conductor Shield | Semi-conducting cross-linked copolymer |
|---|---|
| Insulation Shield | Strippable semi-conducting cross-linked copolymer |
| Metallic Shield | 5 mil copper tape, helically wrapped with 25% overlap |
| Diameter Over Shield | 0.94 in (2.39 cm) |
| Grounding Conductor | One #6 AWG, Class B compressed stranded bare copper |
Jacket & Armor
| Filler | Non-hygroscopic, non-wicking fillers in the interstices |
|---|---|
| Binder | Polypropylene tape |
| Inner Jacket | PVC |
| Inner Jacket Thickness | 110 mils (2.79 mm) |
| Armor | Aluminum interlocked armor (AIA) |
| Diameter Over Armor | 2.644 in (6.72 cm) |
| Outer Jacket | Red polyvinyl chloride (PVC) |
| Jacket Thickness | 75 mils (1.91 mm) |
Dimensions & Weight
| Nominal Outside Diameter | 2.8 in (7.11 cm) |
|---|---|
| Approximate Weight | 3,499 lbs/1000 ft (5207 kg/km) |
| Maximum Pull Tension | 2,008 lbs (910.81 kg) |
| Minimum Bend Radius | 19.6 in (49.78 cm) |
Ratings
| Voltage Rating | 25 kV |
|---|---|
| Insulation Level | 100% |
| Conductor Temperature | 105°C normal operation; 140°C emergency overload; 250°C short circuit |
| Maximum Sidewall Pressure | 1000 lbs/ft |
Standards
- ASTM B3 Soft or Annealed Copper Wire
- ASTM B8 Concentric-Lay-Stranded Copper Conductors
- CSA C22.2 No. 174
- CSA C22.2 No. 2556 & No. 0.3 Wire and Cable Test Methods
- CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV
- CSA C68.3 Shielded & Concentric Neutral Power Cable - 5 to 46 kV
- CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating
- CSA HL rating
- CSA SUN RES - for Sunlight Resistant rating
- ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
- ICEA T-29-520 Flame Test (210,000 BTU/Hr)
- IEEE 383 Flame Test (70,000 btu)
- IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
- FT1 Flame Test (1,706 BTU/Hr nominal - Vertical Wire Flame Test)
- AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
This 25kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications, rated FT4, -40°C and HL, with sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids, and flame retardance.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.