Southwire 66844999, Building Wire 1000 kcmil Copper XHHW-2/RW90 Green
Description
Southwire 66844999 is a 1000 kcmil (507 mm²) single-conductor SIMpull XHHW-2/RW90 building wire in green. Its 61-strand Class B compressed bare copper conductor is insulated with flame-retardant, moisture-resistant thermoset cross-linked polyethylene (XLPE) with patented SIMpull Technology, for installation without pulling lubricant. It is rated for wet or dry locations at temperatures not exceeding 90°C.
Southwire 66844999 Technical Specs
Construction
| Conductor Size | 1000 kcmil (507 mm²) |
|---|---|
| Number of Conductors | 1 |
| Strands | 61 |
| Conductor | Class B compressed stranded bare copper per ASTM B3 and B8 |
| Insulation | Flame-retardant and moisture-resistant thermoset cross-linked polyethylene (XLPE) with patented SIMpull Technology |
| Type Designation | XHHW-2/RW90 |
| Insulation Colour | Green |
Dimensions and Weight
| Diameter Over Conductor | 1.117 in (2.84 cm) |
|---|---|
| Insulation Thickness | 80 mils (2.03 mm) |
| Approx. Overall Diameter | 1.285 in (3.26 cm) |
| Copper Content Weight | 3087 lbs/1000 ft (4594 kg/km) |
| Approx. Total Weight | 3236 lbs/1000 ft (4816 kg/km) |
Ratings
| Voltage, XHHW-2 | 600 volts, or 1000 volts for sizes 8 and larger |
|---|---|
| Voltage, RW90 | 600 volts |
| Temperature | Wet or dry locations, not to exceed 90°C |
Features
| Sunlight | Sunlight resistant |
|---|---|
| Cold Bend | -40°C |
| Oil and Gasoline | Gasoline and Oil Resistant II |
| Flame Tests | FT1; FT4, 350 kcmil and larger |
| Cable Tray | CT Rated, 1/0 AWG and larger |
| RoHS/REACH | Compliant |
Standards
| ASTM B3 | Soft or Annealed Copper Wire |
|---|---|
| ASTM B8 | Concentric-Lay-Stranded Copper Conductors |
| UL 44 | Thermoset-Insulated Wires and Cables |
| UL 1685 | Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger) |
| CSA C22.2 No. 38 | Thermoset-insulated wires and cables |
| ICEA S-95-658 (NEMA WC70) | Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy |
| IEEE 1202/FT4 | Flame Test (70,000 BTU/hr) 350kcmil and Larger |
| Federal Specification | A-A-59544 |
| NMX-J-451-ANCE | Thermoset insulated wires and cables |
| NOM-063-SCFI | Electrical Products – Conductors – Safety Requirements |
| Made in America | Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661 |
| NEMA 70901-2-2024 | Make It American Compliance with Domestic Preference Requirements Pt. 2 Wire & Cable |
Southwire 66844999 Applications
- Runs in conduit, cable tray or other recognized raceways for services, feeders and branch circuit wiring.
- Type XHHW-2 is suitable for use in health care facilities per Section 517.160 of the National Electrical Code where a dielectric constant of less than 3.5 may be specified.
- As RW90, it suits open wiring and raceways (except cable troughs and ventilated flexible cableways) in dry or wet locations under the Canadian Electrical Code, including open wiring exposed to the weather.
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.