Southwire 66861599, Metal Clad Cable 4/0 AWG 4C with Ground Stranded Copper THHN 600 V
Description
Southwire 66861599 is an Armorlite® Type MC feeder cable with four 4/0 AWG 19-strand copper Type THHN/THWN conductors in brown, orange, yellow and gray, plus a 3 AWG green insulated copper ground, under aluminum interlocked armor. Rated 600 V; conductors rated 90°C dry as Type THHN/THWN.
Southwire 66861599 Technical Specs
Conductors and Insulation
| Conductor Size | 4/0 AWG |
|---|---|
| Number of Conductors | 4, plus one grounding conductor |
| Conductor | Class B compressed copper per ASTM B3 and ASTM B8 |
| Stranding | 19-strand |
| Conductor Colors | Brown, Orange, Yellow, Gray |
| Insulation | Polyvinyl chloride with nylon sheath, Type THHN/THWN |
| Insulation Thickness | 60 mils (1.52 mm) |
| Diameter Over Conductor | 0.512 in (1.30 cm) |
| Filler | Fillers as needed |
Grounding and Armor
| Grounding Conductor | Green insulated copper ground |
|---|---|
| Ground Size | 3 AWG |
| Binder | Mylar tape |
| Armor | Aluminum interlocked armor |
Dimensions and Weight
| Diameter Over Armor | 1.883 in (4.78 cm) |
|---|---|
| Approximate Weight | 3,413 lbs per 1,000 ft (5,079 kg/km) |
Ratings
| Voltage Rating | 600 V |
|---|---|
| Conductor Temperature Rating | 90°C dry, Type THHN/THWN |
| Anti-Short Bushing | Not required |
Standards and Compliance
| ASTM B3 | Soft or Annealed Copper Wire |
|---|---|
| ASTM B8 | Concentric-Lay-Stranded Copper Conductors |
| UL 83 | Thermoplastic Insulated Wires and Cables |
| UL 1569 | Metal-Clad Cables |
| UL 1479 | Standard for Safety Fire Tests of Penetration Firestops |
| UL 1685 FT4 | Vertical-Tray Fire Propagation and Smoke Release Test |
| IEEE 1202 FT4 | Flame Test (70,000) BTU/hr Vertical Tray Test |
| RoHS-2 | European Directive 2011/65/EU |
| Buy American | Compliant with Buy American Requirements, found in 49 U.S.C. § 5323(j), when ordered as “Made in the USA Only!” |
| Meets or Exceeds | Federal Specification A-A59544 (formerly J-C-30B); NFPA 70 (National Electrical Code), Article 330 |
Southwire 66861599 Applications
- Feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings.
- Fishing through or embedding in plaster.
- Concealed or exposed runs.
- Environmental air-handling spaces per NEC 300.22(C).
- Places of assembly per NEC 518.4 and theaters per NEC 520.5.
- Cable tray and approved raceways.
- Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) and 645.5(E).
- Class I Div. 2, Class II Div. 2 and Class III Div. 1.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.