Southwire 66866099, Armored Cable 2/0 AWG 3C Copper 15 kV Black
Southwire · MPN 66866099
Description
Southwire 66866099 is a 2/0 AWG three-conductor medium-voltage armored cable rated 15 kV at a 133% insulation level. Its 19-strand compressed bare copper conductors carry a semi-conducting conductor shield, 220 mils of no-lead ethylene propylene rubber (NL-EPR), a strippable insulation shield and a 5 mil copper tape shield, with three bare copper grounding conductors sized together at 50% of the phase conductor. Finishing the cable are a PVC inner jacket, aluminum interlocked armor and a black CPE outer jacket.
Southwire 66866099 Technical Specs
Conductors & Insulation
| Conductor Size | 2/0 AWG |
|---|---|
| Number of Conductors | 3 |
| Strand Count | 19 |
| Conductor | Class B compressed stranded bare copper per ASTM B3 and ASTM B8 |
| Insulation | No-lead ethylene propylene rubber (NL-EPR) |
| Insulation Thickness | 220 mils (5.59 mm) |
| Conductor Colors | Black |
| Diameter Over Conductor | 0.405 in (1.03 cm) |
| Diameter Over Insulation | 0.884 in (2.25 cm) |
Shielding & Grounding
| Conductor Shield | Semi-conducting cross-linked copolymer |
|---|---|
| Insulation Shield | Strippable semi-conducting cross-linked copolymer |
| Metallic Shield | 5 mil copper tape, helically wrapped with 25% overlap |
| Diameter Over Shield | 0.944 in (2.40 cm) |
| Grounding Conductor | Three #6 AWG, Class B compressed stranded bare copper, with a combined circular mil of 50% of the phase conductor |
Jacket & Armor
| Filler | Wax paper |
|---|---|
| Binder | Polypropylene tape |
| Inner Jacket | PVC |
| Inner Jacket Thickness | 60 mils (1.52 mm) |
| Armor | Aluminum interlocked armor (AIA) |
| Diameter Over Armor | 2.536 in (6.44 cm) |
| Outer Jacket | Black thermoplastic chlorinated polyethylene (CPE) |
| Jacket Thickness | 75 mils (1.91 mm) |
Dimensions & Weight
| Nominal Outside Diameter | 2.694 in (6.84 cm) |
|---|---|
| Approximate Weight | 3,878 lbs/1000 ft (5771 kg/km) |
| Maximum Pull Tension | 3,194 lbs (1448.77 kg) |
| Minimum Bend Radius | 18.9 in (48.01 cm) |
Ratings
| Voltage Rating | 15 kV |
|---|---|
| Insulation Level | 133% |
| Conductor Temperature | 105°C normal operation; 140°C emergency overload; 250°C short circuit |
| Maximum Sidewall Pressure | 1000 lbs/ft |
Standards
- ASTM B3 Soft or Annealed Copper Wire
- ASTM B8 Concentric-Lay-Stranded Copper Conductors
- UL 1072 Medium-Voltage Power Cables
- UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
- ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
- AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
It is made in America and compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661.
Southwire 66866099 Applications
- Wet and dry areas, including runs in conduits, ducts, troughs and trays.
- Direct burial installations.
- Class I and II, Division 2 per NEC Article 501 and 502.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.