Southwire 66909999, VFD Cable 600 kcmil 3C Copper RHH/RHW-2 TC-ER 2000V
Description
Southwire 66909999 is a 600 kcmil, 3-conductor 2000V VFD power cable with bare copper conductors, XLPE Type RHH/RHW-2 insulation, three 1 AWG bare copper grounds, a 5 mil copper tape shield and a polyvinyl chloride (PVC) jacket. It is Type TC-ER.
Southwire 66909999 Technical Specs
Construction
| Conductor Size | 600 kcmil |
|---|---|
| Number of Conductors | 3 |
| Conductor | Class B compressed stranded bare copper per ASTM B3 and B8 |
| Strands per Conductor | 61 |
| Insulation | Cross-linked polyethylene (XLPE), Type RHH/RHW-2 |
| Conductor Identification | 1-Black, 2-Red, 3-Blue |
| Grounding Conductors | Three 1 AWG Class B compressed stranded bare copper grounds |
| Shield | 5 mil copper tape shield, minimum 50% overlap |
| Filler | As needed to make round |
| Jacket | Polyvinyl chloride (PVC) |
| Type Designation | TC-ER |
Dimensions and Weight
| Diameter Over Conductor | 0.865 in (2.20 cm) |
|---|---|
| Insulation Thickness | 120 mils (3.05 mm) |
| Diameter Over Shield | 2.409 in (6.12 cm) |
| Jacket Thickness | 115 mils (2.92 mm) |
| Approx. Overall Diameter | 2.639 in (6.70 cm) |
| Copper Weight | 6673 lbs/1000 ft (9931 kg/km) |
| Approx. Weight | 8025 lbs/1000 ft (11943 kg/km) |
Electrical and Thermal Ratings
| Voltage Rating | 2000V |
|---|---|
| Conductor Temperature | 90°C normal operation in wet and dry locations; 130°C emergency overload; 250°C short circuit |
Standards
| ASTM B3 | Soft or Annealed Copper Wire |
|---|---|
| ASTM B8 | Concentric-Lay-Stranded Copper Conductors |
| UL 44 | Thermoset-Insulated Wires and Cables |
| UL 1277 | Electrical Power and Control Tray Cables |
| UL 1685 FT4 | Vertical-Tray Fire Propagation and Smoke Release Test |
| ICEA S-58-679 | Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE) |
| ICEA S-95-658 (NEMA WC70) | Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy |
| ICEA S-138-738 | Power Cables Rated 2000 Volts or Less for use Between Variable Frequency Drives and Motors |
| IEEE 1202 FT4 | Flame Test (70,000) BTU/hr Vertical Tray Test |
| Made in America | Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661 |
Southwire 66909999 Applications
- Variable frequency drive (VFD) power circuits between drives and motors.
- Wet and dry areas: conduits, ducts, troughs and cable trays.
- Direct burial, and aerial runs supported by a messenger.
- Type TC-ER per NEC 336.10.
- Class I, II, and III, Division 2 per NEC Article 501 and 502.