Southwire 67145299, Armored Cable 6 AWG 2C Copper 1 kV Black
Description
Southwire 67145299 is a 6 AWG two-conductor Type TECK 90 armored cable rated 1 kV. Its two 7-strand copper conductors carry 60 mils of XLPE insulation, with a separate 8 AWG uninsulated grounding conductor cabled alongside. A PVC inner jacket, aluminum interlocked armor (AIA) and a black polyvinyl chloride (PVC) outer jacket complete the cable.
Southwire 67145299 Technical Specs
Conductors & Insulation
| Conductor Size | 6 AWG |
|---|---|
| Number of Conductors | 2 |
| Strands per Conductor | 7 |
| Conductor | Class B stranded copper, compressed or compact, per ASTM B3 and B8 |
| Insulation | Cross-linked polyethylene (XLPE) |
| Insulation Thickness | 60 mils (1.52 mm) |
| Conductor Colors | Black, white |
| Diameter Over Conductor | 0.177 in (0.45 cm) |
Grounding, Armor & Jacket
| Grounding Conductor | One 8 AWG uninsulated Class B stranded |
|---|---|
| Inner Jacket | Black polyvinyl chloride (PVC) |
| Inner Jacket Thickness | 65 mils (1.65 mm) |
| Armor | Aluminum interlocked armor (AIA) |
| Diameter Over Armor | 0.941 in (2.39 cm) |
| Outer Jacket | Black polyvinyl chloride (PVC) |
| Jacket Thickness | 45 mils (1.14 mm) |
Dimensions & Weight
| Approximate Outside Diameter | 1.031 in (2.62 cm) |
|---|---|
| Approximate Weight | 537 lbs/1000 ft (799 kg/km) |
| Maximum Pull Tension | 419 lbs (190.06 kg) |
| Minimum Bend Radius | 7.2 in (18.29 cm) |
Ratings & Compliance
| Voltage Rating | 1 kV |
|---|---|
| Type Designation | Type TECK 90 |
| Operating Temperatures | 90°C maximum continuous operating; -25°C minimum installation; -40°C CSA cold bend and impact |
| Location Rating | CSA HL |
| Maximum Sidewall Pressure | 1000 lbs/ft |
| Standards | ASTM B3 Soft or Annealed Copper Wire; ASTM B8 Concentric-Lay-Stranded Copper Conductors; CSA C22.2 No. 174; CSA C22.2 No. 131 Type TECK 90 Cable; CSA C22.2 No. 2556 & No. 0.3 Wire and Cable Test Methods; CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating; CSA HL rating; CSA SUN RES - for Sunlight Resistant rating; CSA AG14 - Acid Gas Compliance; IEEE 383 Flame Test (70,000 btu); IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test |
Southwire 67145299 Applications
- Exposed or concealed wiring in wet or dry locations.
- Ventilated, non-ventilated and ladder-type cable troughs and ventilated flexible cableway, in wet, dry or classified locations.
- Control, lighting and power circuits in pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants.
- The line is rated sunlight resistant.