Southwire 67191899, Building Wire 900 kcmil Stranded Aluminum XHHW-2/RW90 White
Description
Southwire 67191899 is a 900 kcmil single-conductor aluminum building wire with white SIMpull XHHW-2/RW90 insulation, from Southwire's line with AlumaFlex Brand conductors. The 56-strand compact aluminum conductor is insulated with flame-retardant, moisture-resistant thermoset cross-linked polyethylene (XLPE) carrying Southwire's patented SIMpull Technology. Rated for wet or dry locations at temperatures not to exceed 90°C, and up to 1000 volts for all applications.
Southwire 67191899 Technical Specs
Conductor
| Conductor Size | 900 kcmil |
|---|---|
| Metric Size | 456 mm² |
| Conductor | Class B compact stranded bare aluminum per ASTM B800 and ASTM B801, or Single Input Wire (SIW) compact aluminum per ASTM B836 |
| Number of Strands | 56 |
Insulation
| Type Designation | XHHW-2/RW90 |
|---|---|
| Insulation | Flame-retardant, moisture-resistant thermoset cross-linked polyethylene (XLPE) with SIMpull Technology |
| Insulation Color | White |
Dimensions and Weight
| Diameter Over Conductor | 0.999 in (2.54 cm) |
|---|---|
| Insulation Thickness | 80 mils (2.03 mm) |
| Approx. Overall Diameter | 1.167 in (2.96 cm) |
| Aluminum Content Weight | 847 lbs/1000 ft (1260 kg/km) |
| Approx. Total Weight | 989 lbs/1000 ft (1472 kg/km) |
Ratings
| Voltage | Up to 1000 volts, all applications |
|---|---|
| Maximum Temperature | 90°C, wet or dry locations |
Features
| Cable Tray | CT Rated, sizes 1/0 AWG and larger |
|---|---|
| Flame Test | FT4, 350 kcmil and larger |
| Sunlight | Sunlight Resistant, sizes 6 AWG and larger |
| Gas and Oil | Gas and Oil Resistant II, all sizes |
| RoHS/REACH | Compliant |
Standards
| ASTM B800 | 8000 Series Aluminum Alloy Wire |
|---|---|
| ASTM B801 | Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy |
| ASTM B836 | Compact Rounded Stranded Aluminum Conductors |
| UL 44 | Thermoset-Insulated Wires and Cables |
| CSA C22.2 No. 38 | Thermoset-insulated wires and cables |
| ICEA S-95-658 (NEMA WC70) | Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy |
| NMX-J-451-ANCE | Thermoset insulated wires and cables |
| NOM-063-SCFI | Electrical Products – Conductors – Safety Requirements |
Southwire 67191899 Applications
- Pulled in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications, as specified in the National Electrical Code.
- Can be installed without application of pulling lubricant.
- Health care facilities: It is suitable for use per section 517.160 of the NEC where a dielectric constant of 3.5 or less may be specified.
- Under the Canadian Electrical Code, RW90 serves open wiring, including open wiring exposed to the weather, and raceways other than cable troughs and ventilated flexible cableways, in dry or wet locations.
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.