Southwire 67201899, Medium Voltage Cable 2/0 AWG Aluminum 25 kV Black PVC
Description
Southwire 67201899 is a 25 kV shielded medium voltage power cable with a single 2/0 AWG Class B compact stranded 8000 Series aluminum conductor of 12 strands, 320 mils of NL-EPR insulation at the 133% insulation level, a helically wrapped 5 mil copper tape shield and a black polyvinyl chloride (PVC) jacket. Conductor temperature ratings are 105°C for normal operation, 140°C for emergency overload and 250°C for short circuit conditions.
Southwire 67201899 Technical Specs
Construction
| Number of Conductors | 1 |
|---|---|
| Conductor Size | 2/0 AWG |
| Strands | 12 |
| Conductor | Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836 |
| Conductor Shield | Semi-conducting cross-linked copolymer |
| Insulation | No lead ethylene propylene rubber (NL-EPR) |
| Insulation Shield | Strippable semi-conducting cross-linked copolymer |
| Metallic Shield | Helically wrapped 5 mil copper tape, 25% overlap |
| Jacket | Polyvinyl chloride (PVC) |
| Jacket Color | Black |
Dimensions and Weight
| Diameter Over Conductor | 0.376 in (0.96 cm) |
|---|---|
| Diameter Over Insulation | 1.054 in (2.68 cm) |
| Insulation Thickness | 320 mils (8.13 mm) |
| Diameter Over Shield | 1.114 in (2.83 cm) |
| Jacket Thickness | 80 mils (2.03 mm) |
| Overall Diameter (approx.) | 1.294 in (3.29 cm) |
| Weight (approx.) | 829 lbs/1000 ft (1,234 kg/km) |
Installation Limits
| Maximum Pulling Tension | 798 lbs (361.97 kg) |
|---|---|
| Minimum Bending Radius | 15.5 in (39.37 cm) |
| Maximum Sidewall Pressure | 1000 lb/ft |
| Jacket Coefficient of Friction | 0.2 (SIM technology PVC) |
Ratings
| Voltage Rating | 25 kV |
|---|---|
| Insulation Level | 133% |
| Conductor Temperature | 105°C normal operation; 140°C emergency overload; 250°C short circuit |
| Cold Bend | -25°C cold bend and cold impact, marked LTDD, when CSA listed or dual UL/CSA listed |
Standards
| ASTM B801 | Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy |
|---|---|
| ASTM B836 | Compact Rounded Stranded Aluminum Conductors |
| UL 1072 | Medium-Voltage Power Cables |
| UL 1685 FT4 | Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger) |
| CSA C22.2 No.230 | Tray Cables - Rated TC-ER (1/0 AWG and Larger) |
| CSA C22.2 No. 2556 / UL 2556 | Cable Test Methods |
| CSA C68.10 | Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV |
| ICEA S-93-639 (NEMA WC 74) | 5-46 KV Shielded Power Cable |
| ICEA S-97-682 | Standard for Shielded Utility Cable Rated for 5 - 46kV |
| IEEE 1202 | FT4 Flame Test (70,000) BTU/hr Vertical Tray Test (1/0 and Larger) |
| AEIC CS-8 | Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements) |
| Buy America | Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661 |
Southwire 67201899 Applications
- Wet and dry locations.
- Installation in conduits, ducts, troughs and trays.
- Direct burial when installed with a grounding conductor in close proximity that conforms to NEC section 311.36 and 250.4(A)(5).
- Pulling into conduit without lubrication.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.