Southwire 67205799, Power Tray Cable 4/0 AWG 3C Aluminum Alloy XHHW-2 TC-ER 1000V Black
Description
Southwire 67205799 is a 4/0 AWG, 3-conductor Type TC-ER power tray cable with compact stranded 8000 Series aluminum alloy conductors, XLPE Type XHHW-2 insulation, one 2 AWG aluminum grounding conductor and a black sunlight resistant PVC jacket. It is rated 1000V.
Southwire 67205799 Technical Specs
Construction
| Conductor Size | 4/0 AWG |
|---|---|
| Number of Conductors | 3 |
| Conductor | Class B compact stranded 8000 Series aluminum alloy per ASTM B800 and B836 |
| Strands per Conductor | 19 |
| Insulation | Cross-linked polyethylene (XLPE), Type XHHW-2 |
| Conductor Identification | 1-Black, 2-Red, 3-Blue |
| Grounding Conductor | One 2 AWG Class B compact stranded 8000 Series aluminum |
| Filler and Binder | Paper filler; polyester flat thread binder tape |
| Jacket | Black sunlight resistant polyvinyl chloride (PVC) |
| Type Designation | TC-ER |
Dimensions and Weight
| Diameter Over Conductor | 0.474 in (1.20 cm) |
|---|---|
| Insulation Thickness | 55 mils (1.40 mm) |
| Jacket Thickness | 80 mils (2.03 mm) |
| Approx. Overall Diameter | 1.423 in (3.61 cm) |
| Aluminum Weight | 667 lbs/1000 ft (993 kg/km) |
| Approx. Weight | 1105 lbs/1000 ft (1644 kg/km) |
Electrical and Thermal Ratings
| Voltage Rating | 1000V |
|---|---|
| Conductor Temperature | 90°C normal operation in wet and dry locations; 130°C emergency overload; 250°C short circuit |
Standards
| ASTM B800 | 8000 Series Aluminum Alloy Wire |
|---|---|
| ASTM B836 | Compact Rounded Stranded Aluminum Conductors |
| UL 44 | Thermoset-Insulated Wires and Cables |
| UL 1277 | Electrical Power and Control Tray Cables |
| UL 1685 | Vertical-Tray Fire Propagation and Smoke Release Test |
| ICEA S-58-679 | Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE) |
| ICEA S-95-658 (NEMA WC70) | Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy |
| IEEE 1202 FT4 | Flame Test (70,000) BTU/hr Vertical Tray Test |
Southwire 67205799 Applications
- Wet and dry areas: conduits, ducts, troughs and cable trays.
- Direct burial, and aerial runs supported by a messenger.
- Exposed runs (TC-ER) per NEC 336.10.
- Class I, II, and III, Division 2 per NEC Article 501 and 502.
- Silicone free.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.