Southwire 67270699, Armored Cable 500 KCMIL 1C Aluminum 1 kV CSA / 600 V UL Black
Southwire · MPN 67270699
Description
Southwire 67270699 is a 500 KCMIL single-conductor Type TECK 90 armored cable rated 1 kV CSA / 600 V UL. Its 34-strand aluminum conductor carries 90 mils of XLPE insulation, with thirteen 12 AWG uninsulated copper grounding wires cabled alongside. A PVC inner jacket, aluminum interlocked armor (AIA) and a black polyvinyl chloride (PVC) outer jacket complete the cable.
Southwire 67270699 Technical Specs
Conductors & Insulation
| Conductor Size | 500 KCMIL |
|---|---|
| Number of Conductors | 1 |
| Strands per Conductor | 34 |
| Conductor | Class B compact stranded 8000 Series aluminum (ACM) per ASTM B801 |
| Insulation | Cross-linked polyethylene (XLPE) |
| Insulation Thickness | 90 mils (2.29 mm) |
| Diameter Over Conductor | 0.735 in (1.87 cm) |
Grounding, Armor & Jacket
| Grounding Conductors | 13 x 12 AWG uninsulated copper |
|---|---|
| Binder | Mylar |
| Inner Jacket | Black polyvinyl chloride (PVC) |
| Inner Jacket Thickness | 60 mils (1.52 mm) |
| Armor | Aluminum interlocked armor (AIA) |
| Diameter Over Armor | 1.530 in (3.89 cm) |
| Outer Jacket | Black polyvinyl chloride (PVC) |
| Jacket Thickness | 55 mils (1.40 mm) |
Dimensions & Weight
| Approximate Outside Diameter | 1.640 in (4.17 cm) |
|---|---|
| Approximate Weight | 1413 lbs/1000 ft (2103 kg/km) |
| Maximum Pull Tension | 3000 lbs (1360.78 kg) |
| Minimum Bend Radius | 11.4 in (28.96 cm) |
Ratings & Compliance
| Voltage Rating | 1 kV CSA / 600 V UL |
|---|---|
| Type Designation | Type TECK 90 |
| Location Rating | CSA HL |
| Standards | ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy; CSA C22.2 No. 174; CSA C22.2 No. 131 Type TECK 90 Cable; CSA C22.2 No. 2556 / UL 2556 Cable Test Methods; CSA HL rating; CSA SUN RES - for Sunlight Resistant rating; IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test |
Southwire 67270699 Applications
- Exposed or concealed wiring in wet or dry locations.
- Ventilated, non-ventilated and ladder-type cable troughs and ventilated flexible cableway, in wet, dry or classified locations, or direct buried.
- Control, lighting and power circuits in pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants.
- The line is rated sunlight resistant.