Southwire 67291299, Machine Flex® XHHW-2 1000V / RW90 600V Conductor 250 KCMIL Tinned Copper Black
Description
Southwire 67291299 is a Machine Flex® XHHW-2 / RW90 single conductor in 250 KCMIL, made of Class I flexible concentric rope-lay stranded, soft-drawn tinned copper with 608 strands and black, sunlight-, gas- and oil-resistant cross-linked polyethylene (XLPE) insulation. It is rated 1000 V as XHHW-2 and 600 V as RW90. XHHW-2 and RW90 conductors may operate at conductor temperatures up to 90°C in wet and dry locations, 130°C under emergency overload and 250°C under short-circuit conditions.
Southwire 67291299 Technical Specs
Conductor & Insulation
| Conductor Size | 250 KCMIL |
|---|---|
| Number of Conductors | 1 |
| Conductor Material | Soft-drawn tinned copper |
| Stranding | Class I, flexible concentric rope-lay |
| Strand Count | 608 |
| Diameter Over Conductor | 0.605 in (1.54 cm) |
| Insulation | Cross-linked polyethylene (XLPE), sunlight, gas and oil resistant |
| Insulation Thickness | 65 mils (1.65 mm) |
| Insulation Colour | Black |
Dimensions & Weight
| Approx. Outside Diameter | 0.746 in (1.89 cm) |
|---|---|
| Approx. Weight | 848 lbs/1000 ft (1,262 kg/km) |
Ratings
| Voltage Rating | XHHW-2: 1000 V; RW90: 600 V |
|---|---|
| Type Designations | XHHW-2, RW90 |
Compliance & Standards
| Standards | ASTM B3 Soft or Annealed Copper Wire; ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire; ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors; UL 44 Thermoset-Insulated Wires and Cables; UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger); CSA C22.2 No. 38 Thermoset-insulated wires and cables; ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy |
|---|
Sunlight Resistance. CE/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in the RoHS-2 (2011/65/EU) Directive. Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661.
Southwire 67291299 Applications
- Conduit, cable tray and other recognized raceways.
- Intended circuits are service, feeders and branch circuit wiring, as specified in the National Electric Code (NEC) and the Canadian Electrical Code (CE Code).
- The flexible tinned stranding eases installation where space is limited.
- Electrical equipment in industrial facilities with harsh chemical environments, telecommunications applications and data centers.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.