Southwire 67335999, Medium Voltage Cable 1 AWG Copper 5 kV 133% / 8 kV 100% Black PVC
Description
Southwire 67335999 is a shielded medium voltage power cable rated 5 kV at the 133% insulation level and 8 kV at the 100% insulation level, with a single 1 AWG Class B compressed stranded bare copper conductor of 19 strands, 115 mils of TRXLPE insulation, a helically wrapped 5 mil copper tape shield and a black polyvinyl chloride (PVC) jacket. Conductor temperature ratings are 105°C for normal operation, 140°C for emergency overload and 250°C for short circuit conditions.
Southwire 67335999 Technical Specs
Construction
| Number of Conductors | 1 |
|---|---|
| Conductor Size | 1 AWG |
| Strands | 19 |
| Conductor | Class B compressed stranded bare copper per ASTM B3 and ASTM B8 |
| Conductor Shield | Semi-conducting cross-linked copolymer |
| Insulation | Tree retardant cross-linked polyethylene (TRXLPE) |
| Insulation Shield | Strippable semi-conducting cross-linked copolymer |
| Metallic Shield | Helically wrapped 5 mil copper tape, 25% overlap |
| Jacket | Polyvinyl chloride (PVC) |
| Jacket Color | Black |
Dimensions and Weight
| Diameter Over Conductor | 0.322 in (0.82 cm) |
|---|---|
| Diameter Over Insulation | 0.590 in (1.50 cm) |
| Insulation Thickness | 115 mils (2.92 mm) |
| Diameter Over Shield | 0.650 in (1.65 cm) |
| Jacket Thickness | 55 mils (1.40 mm) |
| Overall Diameter (approx.) | 0.800 in (2.03 cm) |
| Weight (approx.) | 514 lbs/1000 ft (765 kg/km) |
Installation Limits
| Maximum Pulling Tension | 669 lbs (303.45 kg) |
|---|---|
| Minimum Bending Radius | 9.6 in (24.38 cm) |
| Maximum Sidewall Pressure | 1000 lb/ft |
| Jacket Coefficient of Friction | 0.2 (SIM technology PVC) |
Ratings
| Voltage Rating | 5 kV 133% / 8 kV 100% |
|---|---|
| Insulation Level | 133% at 5 kV; 100% at 8 kV |
| Conductor Temperature | 105°C normal operation; 140°C emergency overload; 250°C short circuit |
Standards
| ASTM B3 | Soft or Annealed Copper Wire |
|---|---|
| ASTM B8 | Concentric-Lay-Stranded Copper Conductors |
| UL 1072 | Medium-Voltage Power Cables |
| ICEA S-93-639 (NEMA WC 74) | 5-46 KV Shielded Power Cable |
| ICEA S-97-682 | Standard for Shielded Utility Cable Rated for 5 - 46kV |
| AEIC CS-8 | Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements) |
| Buy America | Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661 |
Southwire 67335999 Applications
- Wet and dry locations.
- Installation in conduits, ducts and troughs.
- Direct burial when installed with a grounding conductor in close proximity that conforms to NEC section 311.36 and 250.4(A)(5).
- Pulling into conduit without lubrication.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.