Southwire 67753799, Machine Flex Flexible Tray Cable 12 AWG 4C Copper THHN TC-ER Black
Description
Southwire 67753799 is a 12 AWG 4-conductor Machine Flex® flexible power tray cable with Class K flexible stranded bare annealed copper conductors, polyvinyl chloride (PVC) with nylon layer Type THHN insulation and a black thermoplastic elastomer (TPE) jacket. It is designated Type TC-ER/WTTC/ITC/PLTC/MTW and carries a 600/1000V rating. One of the 4 conductors is a green ground with a yellow stripe; the other 3 are numbered.
Southwire 67753799 Technical Specs
Construction
| Conductor Size | 12 AWG |
|---|---|
| Number of Conductors | 4, including one green/yellow ground |
| Conductor | Class K flexible stranded bare annealed copper per ASTM B3, B172 and B174 |
| Strands per Conductor | 65 |
| Insulation | Polyvinyl chloride (PVC) with nylon layer, Type THHN |
| Conductor Identification | 1-One, 2-Two, 3-Three, per ICEA S-58-679 Method 4 |
| Grounding Conductor | One green ground with yellow stripe, Type THHN |
| Jacket | Black thermoplastic elastomer (TPE) |
| Type Designation | TC-ER/WTTC/ITC/PLTC/MTW |
Dimensions and Weight
| Diameter Over Conductor | 0.094 in (0.24 cm) |
|---|---|
| Insulation Thickness | 20 mils (0.51 mm) |
| Jacket Thickness | 50 mils (1.27 mm) |
| Approx. Overall Diameter | 0.420 in (1.07 cm) |
| Minimum Bend Radius | 1.7 in (4.32 cm) |
| Copper Weight | 81 lbs/1000 ft (121 kg/km) |
| Approx. Total Weight | 137 lbs/1000 ft (204 kg/km) |
Electrical and Thermal Ratings
| Voltage Rating | 600/1000V |
|---|---|
| Conductor Temperature | 75°C wet locations; 90°C dry locations; 130°C emergency overload; 150°C short circuit |
| Cold Impact | -40°C |
| AC Resistance at 75°C | 2.137 |
| Allowable Ampacity, Raceway, 75°C | 20 |
| Allowable Ampacity, Raceway, 90°C | 24 |
Standards
| ASTM B172 | Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors |
|---|---|
| ASTM B174 | Bunch-Stranded Copper |
| UL 13 | Power-Limited Circuit Cables |
| UL 83 | Thermoplastic Insulated Wires and Cables |
| UL 1277 | TC-ER |
| UL 2250 | Instrumentation Tray Cable |
| UL 2277 | Type WTTC |
| CSA C22.2 No. 239 | Control and instrumentation cables |
| ICEA S-58-679 | Control Cable Conductor Identification Method 4 |
| ICEA S-95-658 (NEMA WC70) | Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy |
| IEEE 1202 FT4 | Flame Test (70,000) BTU/hr Vertical Tray Test |
| NFPA 79 | Electrical Standard for Industrial Machinery |
| CE/RoHS-2 | The CE Marking has been applied solely to express the conformance to the material restrictions identified in the RoHS-2 (2011/65/EU) Directive |
| Made in America | Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661 |
Southwire 67753799 Applications
- Wet and dry areas, in conduits, ducts, troughs and cable trays, and direct burial.
- Exposed runs as Type TC-ER per NEC 336.10.
- Class I, II, Division 2 per NEC Article 501 and 502.
- Power for CNC machines, grinding, cutting, metal forming, buffing, bottling equipment, conveyors, processing and packaging equipment, assembly lines and control panels.
- Food and beverage, oil sands, plant expansion, wind energy and data center installations.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.