Southwire 67762999, Armored Cable 750 KCMIL 3C Aluminum 15 kV Black
Southwire · MPN 67762999
Description
Southwire 67762999 is a 750 KCMIL three-conductor medium-voltage armored power cable rated 15 kV, 173% insulation level. Its three 58-strand compact aluminum conductors carry NL-EPR insulation with semi-conducting conductor and insulation shields and a 5 mil copper tape shield, and three 1 AWG bare copper grounding conductors run with them, sized together at 50% of the phase conductor. Aluminum interlocked armor (AIA) and a black polyvinyl chloride (PVC) outer jacket complete the cable.
Southwire 67762999 Technical Specs
Conductors & Insulation
| Conductor Size | 750 KCMIL |
|---|---|
| Number of Conductors | 3 |
| Strands per Conductor | 58 |
| Conductor | Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836; a conductor separator is used at 500 kcmil and larger |
| Insulation | No-lead ethylene propylene rubber (NL-EPR) |
| Insulation Level | 173% |
| Diameter Over Conductor | 0.908 in (2.31 cm) |
Shielding
| Conductor Shield | Semi-conducting cross-linked copolymer |
|---|---|
| Insulation Shield | Strippable semi-conducting cross-linked copolymer |
| Metallic Shield | Helically wrapped 5 mil copper tape, 25% overlap |
| Diameter Over Shield | 1.556 in (3.95 cm) |
Grounding, Armor & Jacket
| Grounding Conductors | Three 1 AWG Class B compressed stranded bare copper grounding conductors, sized together at 50% of the phase conductor |
|---|---|
| Filler | Non-hygroscopic fillers as needed |
| Binder | Polypropylene tape |
| Armor | Aluminum interlocked armor (AIA) |
| Diameter Over Armor | 3.732 in (9.48 cm) |
| Outer Jacket | Black polyvinyl chloride (PVC) |
| Jacket Thickness | 90 mils (2.29 mm) |
Dimensions & Weight
| Approximate Outside Diameter | 3.920 in (9.96 cm) |
|---|---|
| Approximate Weight | 7012 lbs/1000 ft (10435 kg/km) |
| Maximum Pull Tension | 13500 lbs (6123.49 kg) |
| Minimum Bend Radius | 27.4 in (69.60 cm) |
Ratings & Compliance
| Voltage Rating | 15 kV |
|---|---|
| Operating Temperatures | 105°C normal operation; 140°C emergency overload; 250°C short circuit |
| Location Rating | Class I and II, Division 2 per NEC Article 501 and 502 |
| Maximum Sidewall Pressure | 1000 lbs/ft |
| Silicone Content | Silicone free |
| Standards | ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy; ASTM B836 Compact Rounded Stranded Aluminum Conductors; UL 1072 Medium-Voltage Power Cables; UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test; ICEA S-58-679 Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE); ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable; ICEA S-97-682 Standard for Shielded Utility Cable Rated for 5 - 46kV; AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements) |
| Made in America | Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661 |
Southwire 67762999 Applications
- Wet and dry areas, conduits, ducts, troughs and trays, along with direct burial.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.