Southwire 67771999, Metal Clad Cable 500 KCMIL 3C with Ground Stranded Aluminum XHHW-2 Black Jacket
Description
Southwire 67771999 is an Armorlite® jacketed Type MC aluminum feeder cable with three 500 KCMIL 34-strand aluminum XHHW-2 conductors (brown, orange and yellow) and a #1/0 ground under aluminum interlocked armor and a black PVC jacket. It is suitable for wet locations per NEC 330.10(A)(11), with XHHW-2 conductors rated 90°C dry and wet.
Southwire 67771999 Technical Specs
Conductors and Insulation
| Conductor Size | 500 KCMIL |
|---|---|
| Number of Conductors | 3, plus a grounding conductor |
| Conductor | Class B compact stranded 8000 series aluminum per ASTM B800 and ASTM B801 |
| Stranding | 34-strand |
| Conductor Colors | Brown, Orange, Yellow |
| Insulation | Cross-linked polyethylene (XLPE), Type XHHW-2 |
| Insulation Thickness | 70 mils (1.78 mm) |
| Diameter Over Conductor | 0.735 in (1.87 cm) |
Grounding and Armor
| Grounding | #1/0 AWG ground conductor |
|---|---|
| Ground Size | 1x1/0 |
| Filler | Fillers as needed |
| Binder | Mylar tape |
| Armor | Aluminum interlocked armor |
| Jacket | Black polyvinyl chloride (PVC), sunlight resistant and corrosion resistant |
| Jacket Thickness | 60 mils (1.52 mm) |
Dimensions and Weight
| Diameter Over Armor | 2.214 in (5.62 cm) |
|---|---|
| Approximate Overall Diameter | 2.34 in (5.94 cm) |
| Approximate Weight | 2704 lbs per 1,000 ft (4024 kg/km) |
Ratings
| Temperature Rating | 90°C dry / wet (Type XHHW-2) |
|---|---|
| Location | Suitable for wet locations per NEC 330.10(A)(11) |
Standards and Compliance
| ASTM B800 | 8000 Series Aluminum Alloy Wire |
|---|---|
| ASTM B801 | Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy |
| UL 44 | Thermoset-Insulated Wires and Cables |
| UL 1569 | Metal-Clad Cables |
| UL 1479 | Standard for Safety Fire Tests of Penetration Firestops |
| UL 1685 FT4 | Vertical-Tray Fire Propagation and Smoke Release Test |
| IEEE 1202 FT4 | Flame Test (70,000) BTU/hr Vertical Tray Test |
| Buy American | Compliant with Buy American Requirements, found in 49 U.S.C. § 5323(j), when ordered as “Made in the USA Only!” |
| Meets or Exceeds | Federal Specification A-A59544 (formerly J-C-30B); NFPA 70 (National Electrical Code), Article 330 |
Southwire 67771999 Applications
- Feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings.
- Locations exposed to cinder fills, strong chlorides, caustic alkalis, or vapors of chlorine or hydrochloric acids.
- Fished or embedded in plaster.
- Concealed or exposed installations.
- Places of assembly per NEC 518.4 and theaters per NEC 520.5.
- Cable tray and approved raceways, or aerial installation on a messenger.
- Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) and 645.5(E).
- Class I Div. 2, Class II Div. 2 and Class III Div. 1.