Southwire 67841099, Metal Clad Cable 750 KCMIL 3C with Ground Stranded Aluminum THHN 600 V
Description
Southwire 67841099 is an Armorlite® Type MC aluminum feeder cable with three 750 KCMIL 53-strand aluminum THHN/THWN conductors (brown, orange and yellow) and a #3/0 AWG green insulated aluminum ground under aluminum interlocked armor. It is rated 600 V; its conductors are rated 90°C dry.
Southwire 67841099 Technical Specs
Conductors and Insulation
| Conductor Size | 750 KCMIL |
|---|---|
| Number of Conductors | 3, plus a grounding conductor |
| Conductor | Class B compact stranded 8000 series H14/H24 aluminum per ASTM B800 and B801, or compact round stranded 8000 series H14/H24 aluminum per ASTM B800 and B836 |
| Stranding | 53-strand |
| Conductor Colors | Brown, Orange, Yellow |
| Insulation | Polyvinyl chloride with nylon sheath, Type THHN/THWN |
| Insulation Thickness | 80 mils (2.03 mm) |
| Diameter Over Conductor | 0.908 in (2.31 cm) |
Grounding and Armor
| Grounding | Green insulated aluminum ground, #3/0 AWG |
|---|---|
| Ground Size | 1x3/0 |
| Filler | Fillers as needed |
| Binder | Mylar tape |
| Armor | Aluminum interlocked armor |
Dimensions and Weight
| Diameter Over Armor | 2.621 in (6.66 cm) |
|---|---|
| Approximate Weight | 3278 lbs per 1,000 ft (4878 kg/km) |
Ratings
| Voltage Rating | 600 V |
|---|---|
| Temperature Rating | 90°C dry (Type THHN/THWN) |
Standards and Compliance
| ASTM B800 | 8000 Series Aluminum Alloy Wire |
|---|---|
| ASTM B801 | Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy |
| ASTM B836 | Compact Rounded Stranded Aluminum Conductors |
| UL 83 | Thermoplastic Insulated Wires and Cables |
| UL 1569 | Metal-Clad Cables |
| UL 1479 | Standard for Safety Fire Tests of Penetration Firestops |
| UL 1685 FT4 | Vertical-Tray Fire Propagation and Smoke Release Test |
| IEEE 1202 FT4 | Flame Test (70,000) BTU/hr Vertical Tray Test |
| RoHS Compliant | Lead-Free, Silicone-Free |
| Buy American | Compliant with Buy American Requirements, found in 49 U.S.C. § 5323(j), when ordered as “Made in the USA Only!” |
| Meets or Exceeds | Federal Specification A-A59544 (formerly J-C-30B); NFPA 70 (National Electrical Code), Article 330 |
Southwire 67841099 Applications
- Feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings.
- Power and lighting circuits.
- Fished or embedded in plaster.
- Concealed or exposed installations.
- Places of assembly per NEC 518.4 and theaters per NEC 520.5.
- Environmental air-handling spaces per NEC 300.22(C).
- Cable tray and approved raceways, or aerial installation on a messenger.
- Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) and 645.5(E).
- Class I Div. 2, Class II Div. 2 and Class III Div. 1.
- Anti-short bushings are not required for use with MC cable per NEC and UL.